Why a plasma rotates light
01 / A radio wave meets a magnetic plasma
Faraday rotation is the turning of a linearly polarised electromagnetic wave as it passes through a transparent material with a magnetic field parallel to its direction of travel. In this laboratory the medium is an electron plasma: a population of mobile electrons with fixed positive-ion background. A longitudinal magnetic field makes electrons respond differently to right- and left-circularly polarised radio waves. Since a linear wave is the sum of two circular waves, their different propagation phases rotate the reconstructed linear polarisation. Unlike a simple optical filter, the medium can change polarisation without absorbing power when both normal modes propagate.
02 / Set up the instrument
Use the five numbered modes at the top to switch scientific questions. In the 3D chamber, drag empty space to orbit, scroll or pinch to zoom, and Shift-drag or right-drag to pan. The amber probe can be dragged along the plasma to measure the local accumulated rotation. In the layered experiment, click a coil handle and drag up or down to change that cell’s signed magnetic field. Pause freezes the visibly slowed radio carrier, not the underlying equilibrium solution. Reset returns to the selected mode’s initial physical settings; Camera restores the viewpoint. Save genuine calculated observations to the notebook and export a CSV.
03 / Cold magnetoionic dispersion
For a wave propagating parallel to a uniform magnetic field, the ideal collisionless electron-plasma eigenmodes have relative permittivities n²R = 1 − X/(1 − Y) and n²L = 1 − X/(1 + Y), where X = ω²p/ω² and Y = ωc/ω. Here ω = 2πf, ω²p = nₑe²/(ε₀mₑ), and ωc = eB∥/mₑ. B∥ is signed: reversing it exchanges the two circular modes. In a propagating region the wavenumber is k = (ω/c)√n². For negative n² it becomes imaginary and the field amplitude decays exponentially. Near the collisionless cyclotron resonance the model is singular, so the simulator labels that idealisation rather than assigning a physically meaningful finite measurement.
The accumulated angle in a non-absorbing column is θ = (kL − kR)L/2, with a sign convention defined by the displayed analyser. The code multiplies complex eigenmode transmission factors for successive layers and reconstructs the detector’s electric field. Its physical observables are the Stokes parameters I = |Eₓ|² + |Eᵧ|², Q = |Eₓ|² − |Eᵧ|², U = 2Re(EₓEᵧ*), and V = 2Im(EₓEᵧ*). The position angle is one half of atan2(U,Q); it is indistinguishable modulo 180 degrees. With evanescence, the output can become elliptical rather than merely rotated.
04 / Five experiments with testable predictions
Polarisation chamber: Adjust density, signed B, path length and frequency. Predict that rotation is zero at B = 0 or nₑ = 0, and reverses sign when B reverses. Turn the analyser to maximise the detected power and check Malus’ law. Scan the probe along the tube; angle accumulates with distance. At low frequencies the high-frequency formula becomes inaccurate, which is why this mode reports the exact cold-plasma result separately.
Cut-off spectrum: Sweep frequency through the R/L dispersion curves and transmission graph. Compare the electron plasma frequency fₚ with the signed cyclotron frequency f꜀. Find a band where one circular component becomes evanescent: the received field then acquires ellipticity and the receiver power falls. Predict whether increasing electron density moves a cut-off up or down.
Layered field scanner: Six adjacent cells have independent density and magnetic-field multipliers. First use alternating positive and negative cells. Then observe the cumulative angle at the draggable probe and compare it with the signed field profile. The code composes circular-wave phases layer by layer; local opposite fields can cancel the integrated rotation.
Stokes radio receiver: Generate a deterministic multi-frequency spectrum, measure Q and U in each channel, unwrap position angles modulo π, and fit their slope versus wavelength squared. The fitted rotation measure and its residual are compared with the high-frequency formula. At frequencies not far above the plasma and cyclotron scales the exact magnetoionic curve bends away from a straight λ² law.
Cosmic Faraday screen: Switch from metre-scale laboratory units to astrophysical electron density in cm⁻³, magnetic field in microgauss and path length in parsecs. Vary transverse RM gradients and receiver channel bandwidth. Predict that unresolved source patches with different rotation angles partially cancel one another’s Stokes Q and U. Increasing bandwidth can likewise reduce measured fractional polarisation even when individual rays propagate without energy loss.
05 / Rotation measure, scales and applications
Well above all plasma resonances, θ ≈ RM λ², where RM = K∫nₑB∥dl and K = e³/(8π²ε₀m²ₑc³) ≈ 2.631×10⁻¹³ in SI units. In astronomical units this is RM ≈ 0.812∫nₑ(cm⁻³) B∥(μG) dl(pc) rad/m². Its sign probes the directed magnetic field; electron density also contributes, so independent density estimates help infer the field strength.
06 / Assumptions, interpretation and glossary
The laboratory model assumes a cold, uniform-density electron fluid inside each cell, a static longitudinal magnetic field, plane waves, stationary ions, zero collisions and linear propagation at normal incidence. It excludes oblique Appleton–Hartree propagation, collisions, non-linear plasma effects, cyclotron damping, multiple interface reflections, waveguide modes, scattering, instrumental noise and actual antenna response. Ideal evanescent propagation is modelled with exponential attenuation; no finite cyclotron-resonance lineshape is claimed. The cosmic beam is a sampled Gaussian angular weighting of a prescribed linear RM gradient, not a full 3D magnetohydrodynamic simulation.
Glossary: eigenmode — independent circular polarisation supported by the medium; cut-off — frequency region where n² becomes negative; Stokes parameters — four measured quantities describing polarisation; rotation measure — slope of polarisation angle versus λ² in the high-frequency regime; evanescence — exponential spatial decay rather than forward power propagation; depolarisation — cancellation caused by unresolved differing polarisation angles.
Explore further: Why can reversed adjacent cells yield nearly zero integrated RM yet exhibit local rotation? When does an exact polarisation curve cease to obey a λ² law? How could multiple sightlines distinguish a magnetic-field reversal from a change in electron density?