Cherenkov thresholdTune particle speed and radiator index to cross the emission threshold.
RADIATOR MEDIUMMAT / 01
Dispersive dielectric · n ≈ 1.337 at band centre
QUICK PRESETSLOAD / 03
✳Scientific mission deckTen auto-checked tasks. Calculate, predict, then verify against the model.
FOUNDATIONMISSION 01 / 10
The water threshold
At 450 nm, what is the minimum β for Cherenkov emission in water?
β
Use the hint if you need a starting point.
Answers are checked numerically with a tolerance appropriate to the model and displayed units.
FIELD MANUAL / CH–01When a particle outruns light
A practical guide to coherent optical emission in dielectric media.
01 · Phenomenon & principle
Cherenkov radiation is emitted when a charged particle moves through a dielectric faster than the phase velocity of light in that medium. Nothing outruns light in vacuum: the condition is βc > c/n, or βn > 1. The emitted wavelets interfere constructively on a cone whose half-angle obeys cos θc = 1/(βn). This is the optical analogue of a sonic boom, but it is electromagnetic radiation generated by the particle's field polarising the medium.
02 · Equations & variables
The threshold speed is βthr = 1/n. For a particle of mass m, the threshold momentum is pthr = m/√(n²−1). The Frank–Tamm spectrum is d²N/(dx dλ) = 2παz²/λ² [1−1/(β²n²(λ))] when βn(λ) > 1. Here α is the fine-structure constant, z is charge in units of e, λ is vacuum wavelength and x is track length. The yield scales with z² and is weighted toward short wavelengths, while dispersion changes the cone angle across the band.
03 · Operate the chamber
Select a radiator, tune β and the optical band, then press Run Beam to move the particle through the chamber. Drag the gold particle handle along the beam axis to reposition the emission point. Drag the gold detector hub to introduce a sensor-plane offset. Orbit with a left drag, pan with Shift + drag or the right mouse button, and zoom with the wheel or a two-finger pinch. Every slider changes the calculation and redraws both data plots.
04 · Six experimental modes
Threshold explorer: vary β and observe the sharp onset of yield and cone angle. Spectral microscope: narrow the wavelength band and inspect the Frank–Tamm spectrum alongside material dispersion. Ring-imaging detector: change focal distance and infer θc from the sensor-ring radius R = f tan θc. Timing laboratory: compare particle flight time with photon group delay; pulse propagation depends on ng = n − λ dn/dλ. Radiator foundry: compare water, fused silica, aerogel and air for threshold and photon yield. Particle identification: combine a measured cone angle with known momentum to reconstruct mass.
05 · Suggested investigations
Predict the water threshold before moving β through it. Keep β fixed and compare the ring radii produced by blue and red photons. Find a momentum range where a pion radiates in silica but a kaon does not. Increase |z| from one to two and test whether the yield quadruples. Compare the group-delay curve with the phase-index curve. Save each result to the notebook and export the run log as CSV for a lab report.
06 · Applications & engineering
Ring-imaging Cherenkov (RICH) detectors identify charged hadrons in accelerator experiments by measuring their velocity. Water-Cherenkov observatories use large transparent volumes and photomultiplier sensors to detect charged secondaries from neutrino interactions and cosmic rays. The same principle appears in compact particle counters, beam diagnostics, radiation dosimetry and studies of optical properties of materials. The characteristic blue glow in reactor pools is a familiar macroscopic example, although the exact spectrum depends on the medium and detector response.
07 · Model assumptions & limits
The radiator uses a Cauchy dispersion fit n(λ) = A + B/λ² + C/λ⁴ with wavelength in micrometres. It is a compact visible-band approximation, not a certified optical-constants database. The Frank–Tamm equation is integrated over the selected band using a trapezoidal numerical quadrature. Expected detected photons apply a bulk exponential attenuation, a fixed collection factor and the selected sensor quantum efficiency. The 3D photon rays are a deterministic visual sample of the cone, not a one-to-one rendering of every emitted photon. The timing model uses group index and a straight optical path; it omits detailed mirror aberrations, scattering, wavelength-dependent sensor response, boundary refraction and stochastic photoelectron statistics.
08 · Glossary & further questions
Phase index: n = c/vphase. Group index: ng = c/vgroup. Frank–Tamm yield: spectral photon production per unit track length. RICH: ring-imaging Cherenkov detector. Quantum efficiency: probability that an incident photon produces a photoelectron. Dispersion: wavelength dependence of refractive index. Why does a higher-index medium lower the threshold? How could chromatic dispersion blur a measured ring? What extra information would a second radiator provide when separating two particle species?
CHERENKOV OBSERVATORY · SCIENTIFIC MODEL NOTE 01
LOCAL EXPERIMENT LOGMeasurement notebook
Save, compare and export model readings from this browser session.
▤
+No readings saved yetRun an experiment and save a measurement to start your log.