A tiny charged sphere is suspended or driven through air by gravity and an electric field. Its terminal speeds reveal the charge.
TERMINAL FALLvf = 2 a² Δρ g C / (9 η)
CHARGE FROM FALL + RISEq = 6 π η a (vf + vr) / (E C)
SLIP CORRECTIONC = 1 + b / (p a)
BROWNIAN DIFFUSIOND = kB T C / (6 π η a)
σx = √(2 D t)
The drag correction matters because a micrometre-scale drop is not large compared with the mean free path of air molecules. The simulator uses Millikan’s empirical first-order pressure correction, with b = 0.0006254 when pressure is in mmHg and radius in cm.
Noise model. Each timed transit receives an independent Gaussian Brownian displacement with variance 2Dt, converted to a first-order timing offset at the expected crossing. The historical crosshair, voltage, plate-gap and viscosity calibration limits are represented as independent bounded calibration offsets, held fixed within one measurement set. The original paper does not specify a numerical chronoscope jitter, so none is invented here.
Historical anchors. Millikan reported a 5,300 V battery, 16.00 mm plate spacing, clock-oil density 0.9199 g/cm³ at 23 °C, and transit intervals generally kept between 10 and 40 s. The chosen drop radius, crosshair distance and repeated-pair count are illustrative controls, not copied raw observations.
What is simplified. The model assumes spherical drops, laminar Stokes drag, terminal motion, a uniform field, constant temperature and a first-order slip correction. It omits charge loss during a transit, convection, evaporation, optical focus errors and detailed chronoscope response. The simulated rerun is not a transcription of Millikan’s 58-drop table.
This educational reconstruction is not affiliated with the University of Chicago, the American Physical Society or any historical institution.