Tesla Coil Arcs — 2D Resonant Transformer Scope

Two coupled resonant circuits: how the energy of the primary capacitor rings over into the secondary, how coupling and tuning change the voltage and the beat period.

Switch to 3D

Presets

Controls

x1

Readouts

Numerical checks

The science

A resonant (air-core) transformer is two tuned circuits. The primary has inductance Lp and capacitor Cp, the secondary has inductance Ls and a small top-load capacitance Cs; the coils share a mutual inductance M = k sqrt(Lp Ls). With currents i1, i2 and capacitor voltages V1, V2 the equations are Lp i1' + M i2' = V1 - Rp i1, M i1' + Ls i2' = -V2 - Rs i2, Cp V1' = -i1, Cs V2' = i2, integrated with RK4. Resonance is w0 = 1/sqrt(Ls Cs); the primary is tuned to it by choosing Cp (the detune slider shifts it).

With coupling k the system has two normal modes at w = w0 / sqrt(1 +- k). Their beating moves the energy from primary to secondary in t = pi / (w_a - w_b) = pi / dw, about 1 / (4 f0 k) for weak coupling. Because the energy 1/2 Cp V0^2 ends up on a tiny capacitance, the ideal secondary voltage is V2 = V0 sqrt(Cp / Cs), hundreds of times the primary voltage; in a real coil the arc starts to lose energy before this and the voltage is limited by corona and breakdown (air fails near 3 MV/m in a uniform field, much less near sharp points).

Simplifications: lumped parameters (a real secondary is a distributed transmission line), no spark gap or switch model, no arc load, constant coupling, only linear resistance for losses. Checks below: energy conservation with zero resistance and the beat time against pi/dw. Educational physics; high voltage is dangerous and this is not a build guide.