Left Ventricle PV Loop

2D companion of the 3D ventricle lab: a stiffening chamber fills, squeezes blood into an elastic artery and relaxes, tracing a loop whose area is the stroke work.

Switch to 3D

Presets

Playback

Apparatus

Model checks

The science

What is modelled

The ventricle is a chamber whose stiffness (elastance) rises and falls with each beat. Blood enters through the inlet valve while the chamber is soft, the valve shuts as it stiffens, the outlet valve opens when the pressure exceeds the aorta and blood is ejected into an elastic artery that drains through the body resistance.

Equations

  • Chamber P = E(t) (V − V0), with E(t) between a passive and a peak value.
  • Valves as diodes: Q = max(0, ΔP) / R.
  • Volume dV/dt = Qin − Qout.
  • Windkessel C dPao/dt = Qout − (Pao − Pv) / Rs.

Checks run in the page

  • Stroke volume from the loop against integrated aortic flow.
  • Mean pressure against venous pressure plus flow times resistance.
  • Loop area (shoelace) against the integral of P dV.
  • Diastolic decay time against R C.

Honest simplifications

A lumped, single-chamber educational model: fixed valve resistances, an idealised elastance curve, a constant venous pressure and no atrium or coronary flow. It is not diagnostic software.

What to try
  • Press Raised afterload: the ventricle must develop more pressure and the stroke volume falls.
  • Press Exercise to see a shorter beat, higher output and a narrower loop.
  • Press Weak ventricle and watch the ejection fraction drop.
Pressure-volume loop
Pressures over a beat
Volume and flows over a beat
Elastance over a beat