What is modelled
A charged particle crossing the gas strips electrons from atoms along its path, about one electron pair per 26 eV it loses. A uniform electric field drags the electrons to the readout plane at a speed that grows with the field and then saturates. On the way they random-walk, which blurs the track in proportion to the square root of the distance. At the readout plane a strong field makes each electron start an avalanche. The arrival time of each electron, times the drift speed, gives its original height; the position on the plane gives the other coordinate.
Equations
- Number of electrons
N = Edep / WwithW = 26 eVand varianceF N,F = 0.2. - Drift speed
vd = vmax (E/E0) / (1 + E/E0)(a simple saturating curve), drift timet = L / vd. - Diffusion
σ = D* √L, time spreadσ/vd. - Townsend avalanche
dn/dx = α n,α = A p exp(-B p / E), soG = exp(α d). - Track fit slope error
σ / √Σ(x - x̄)².
Checks run in the page
- A random walk of 3000 electrons against L / v and the diffusion spread.
- Primary ionisation counts and their Fano-factor variance.
- The avalanche differential equation integrated across the gap against the set gain.
- Least-squares track fits against the slope-error formula.
Honest simplifications
The drift speed curve and the diffusion coefficient are stand-ins for a real gas mixture (a real one is computed from electron-atom cross sections), the field is perfectly uniform, there is no attachment to impurities, no ion back-flow, no space charge, no transverse diffusion different from longitudinal, no delta rays, and the avalanche is a single-gap parallel plate with a fixed gain rather than a statistical (Polya) distribution. The drawn drift is slowed by a factor of about 100,000. The 3D cutaway is illustrative and its slider labels carry no units.
What to try
- Choose Long drift, big diffusion: the track blurs and the height resolution gets worse as the square root of the distance.
- Choose Low field: the electrons crawl and the drift takes much longer.
- Choose Heavy ionising track: many more electrons, so the gain needed is lower.