Middle ear impedance matching - 3D cutaway

Blender-built eardrum, ossicles, oval window and cochlea; live gain, power transfer and conductive loss.

Switch to 2D

Presets

Playback

Sound

Anatomy

Typical adult: drum 55 mm², footplate 3.2 mm², lever 1.3.

Middle-ear condition

Mass, stiffness, friction, chain gap and perforation reproduce common conductive problems (educational).

Display

Motion is nanometres in reality; it is magnified and slowed here.

Camera

Quality

Layers

Model checks

The science

What the middle ear does

Sound in air carries little force and a large displacement; the fluid-filled cochlea needs a large force and small displacement. Shining sound straight on to fluid reflects almost everything: with specific impedances Zair = ρc ≈ 415 Pa s/m and Zfluid ≈ 1.5×106 Pa s/m the intensity transmission is T = 4 Z1Z2/(Z1+Z2)2 ≈ 0.11 % (about −30 dB). The eardrum (area Ad), the ossicular lever (ratio L) and the small stapes footplate (area Af) form a transformer that raises pressure by T = Ad L / Af (typical 55 mm² × 1.3 / 3.2 mm² ≈ 22, i.e. 27 dB) and lowers velocity by the same factor.

The circuit used here

Everything is referred to the umbo (eardrum) side in SI units. The incident sound acts as a source with blocked force Fb = pd A and the air column on the drum as a radiation resistance Ra = ρc A. In series are friction Rf, the moving mass m and the stiffness k of drum, ligaments and ossicles: Zd = Ra + Rf + j(ωm − k/ω). The lever is an ideal transformer (force ×L, velocity ÷L). Behind it the stapes sees the cochlea as a resistance Rc = Zac Af2 (Zac ≈ 1.2×1010 Pa s/m3, a typical measured input impedance, far lower than a plane-wave fluid column) in series with a compliance Cg that grows when the ossicular chain is interrupted. Then

vu = Fb / (Zd + Zl/L2), Zl = 1/(1/Rc + jωCg), Fs = L (Zl/L2) vu, pressure gain G = (Fs/Af) / pd and power transfer η = ½|Fs|2/Rc / (pd2Ad / 8ρc), the delivered power over the power available from the source. The displayed “gain vs direct air-to-fluid” is 10 log(η / 0.0011).

Maximum power transfer

For a continuous chain the cochlear load seen at the drum is Rc/L2. Power into it is largest when this equals the source impedance magnitude, so the best footplate area is Af,opt = L √(|Zs| / Zac) with Zs = Ra + Rf + j(ωm − k/ω). The experiment graph sweeps Af and finds the numerical maximum.

Conditions you can recreate

Otosclerosis (stapes fixation) raises the stiffness; fluid behind the drum adds mass and friction; a perforation removes drum area; an interrupted chain opens a gap compliance; the stapedius (acoustic) reflex stiffens the chain at loud sounds. “Conductive loss” is the drop of cochlear drive relative to the healthy ear: 20 log10(Ghealthy/G). The cochlear place of a tone is the Greenwood map f = 165.4 (102.1x − 0.88), x = fraction of the 35 mm basilar membrane from the apex.

Independent numerical checks

(1) The circuit differential equations are integrated in the time domain (RK4, lock-in amplitude) and compared with the phasor formula at five tones. (2) In the time domain the average source power must equal the power lost in radiation resistance and friction plus the power into the cochlea. (3) A finite-difference wave simulation of a pulse crossing an air-to-fluid impedance step gives the transmitted energy, compared with 4Z1Z2/(Z1+Z2)2 (the solver contains no formula for it). (4) The footplate-area sweep against the maximum-power-transfer theorem. (5) The lever ratio is measured on the Blender mesh itself (umbo and incus-tip distances from the rotation axis) and compared with the anatomical value 1.3.

Honest simplifications

This is a lumped, linear, single-resonance model. Real eardrums are not rigid pistons (they break up above 1–2 kHz), the ossicles have more than one mode, the round window and the ear-canal acoustics are ignored, and the cochlear load is frequency dependent. Element values (mass 15 mg, stiffness 853 N/m, friction 0.02 N s/m, gap compliance scale, cochlear impedance) are typical or tuned values giving a peak gain of about 23 dB near 1.2 kHz, not measurements of a particular ear. Conductive-loss curves are model illustrations: real audiograms also depend on bone conduction, the inner ear and measurement conditions, and some presets (very stiff chains) show unrealistic gains at high frequency. The wave pattern in the canal and the motion of the parts are magnified and slowed for visibility (the real wavelength at 1 kHz is 343 mm; the real motion is nanometres). Educational only, not medical advice.

What to try
  • Press “Healthy adult ear” and sweep the frequency: gain peaks near 1.2 kHz at about 23 dB, which is the “gain vs direct air-to-fluid” of roughly 26 dB.
  • Open the footplate-area graph: the green dot is the numerical optimum and the dashed line the theorem. The real footplate (3.2 mm²) is close to it at 1 kHz.
  • “Otosclerosis” lifts the stiffness: low tones are hit first (conductive loss graph).
  • “Chain interrupted” opens a gap compliance: the stapes moves far less than the drum and the loss approaches 40–60 dB.
  • “Acoustic reflex” stiffens the chain at 95 dB SPL, reducing low-frequency transmission by about 10 dB.
Loading Blender model...
Pressure gain of the middle ear (cochlea / drum)
Power transfer to the cochlea (dB re available power)
Conductive hearing loss vs healthy ear
Live motion: umbo and stapes footplate (two periods)
Experiment: footplate area vs power transfer
Made with 🟠 Blender · Three.js