OBSERVATORY / 001VAPORLINE / ATMOSPHERIC OPTICS
Preparing scientific instruments•SEED 2553690560801255809
EXPERIMENTAL PHYSICS / GEOMETRICAL OPTICS / 2026 EDITION

When air becomes a lens.

Build mirages with thermal gradients. Trace real rays through invisible layers. Aim into a changing horizon.

LIVE OPTICAL CHAMBER

01 / Inferior Mirage

Ground-heated atmosphere

● NUMERICAL RAY TRACE
3D / STRATIFIED ATMOSPHEREWebGL2
ATMOSPHERIC SECTION · 0–13 mVertical scale exaggerated ~18× for visibility. Rays solved in true SI metres.Drag handles · orbit · scroll zoom · right-drag pan · two-finger pinch
X 520 m  /  Y 13 m
Scan rate0.7 Hz
Animated angular scan changes actual ray launch angle.
DETECTOR MISS—vertical offset
RAY TURNS—gradient-induced
MINIMUM HEIGHT—m above surface
OPTICAL DELAY—ns / path
REFRACTIVITY—N at emitter / ppm
INVARIANT ERROR—|Δ(n cos θ)|

Beam trajectory

Simulated ray path · real measurements

RANGE

Air column analysis

Temperature & phase refractivity

FIELD MANUAL / SCIENTIFIC FOUNDATIONS

The science of a wavering horizon

Original laboratory notes · idealised dry-air geometrical optics · all heights and ranges in SI units

01 / Introduction: a lens without glass

On a hot road, the far horizon can look like water. The apparent reflection is not a glossy road surface: it is light travelling along a curved path through air whose density changes with height. Since the phase refractive index of air depends on density, a steep thermal gradient turns the atmosphere into a continuous, very weak lens. A cold layer can bend light in the opposite direction and distort the altitude of distant objects. These effects are called inferior and superior mirages. The experiment here follows rays instead of inventing an image from a painted heat haze.

02 / Operating the rig

Choose one of five experiments. Use the amber 3D handle to adjust source elevation, the jade handle to adjust detector elevation or distance, and the violet height marker to change the layer centre. Drag empty space to orbit, use right-drag to pan and the wheel or two-finger gesture to zoom. Sliders accept keyboard and touch input. Pause to freeze the angular scanning measurement, then change thermal contrast, vertical scale, wavelength or launch angle and watch both charts respond. The trajectory graph displays calculated altitude against range. The column graph displays temperature, refractivity or its gradient. Record the current state, compare saved curves and export a CSV of readings.

03 / Physical equations

Air is approximated as a dry ideal gas. At the same pressure, warmer air has lower density and therefore smaller n − 1. For standard air, this lab uses the visible-wavelength Edlén-type expression nₛ − 1 = 10⁻⁸[8342.13 + 2406030/(130 − σ²) + 15997/(38.9 − σ²)], where σ = 1/λ with λ in micrometres. We scale that standard phase refractivity by exp(−z/8400) × 288.15/T(z), with z in metres and T in kelvin. The lapse-rate background is −0.0065 K/m. Refractivity is N = 10⁶(n−1), in parts per million.

Fermat’s stationary-optical-path principle gives d/ds(n d𝐫/ds) = ∇n. For our horizontally homogeneous air, setting θ to the ray angle above the horizontal leads to dz/dx = tan θ and dθ/dx = [1/n]dn/dz. A fourth-order Runge–Kutta integrator advances both variables in fixed horizontal steps. The invariant n(z) cos θ should remain constant, and the instrument reports its largest deviation. Optical time is the line integral ∫n ds/c. A ray that touches the ground terminates: our asphalt does not reflect it.

04 / Experiment I: the hot-road inferior mirage

The road mode uses T(z) = Tₐ − 0.0065z + ΔT exp(−z/H). A large positive ΔT and small H heat the lowest air. Index increases with height and a sufficiently grazing downward ray can curve upward without ever touching the ground. Adjust emitter height and angle until the turn counter reaches one. Hypothesis: making H smaller while holding contrast fixed strengthens the near-surface index gradient but also narrows its effective layer. Test the relationship by saving two ray records.

05 / Experiment II: the cold-surface superior mirage

Cold Shelf substitutes −ΔT exp(−z/H). The cold air near the surface is denser, so n usually decreases with altitude there, making a ray curve downward. Try a high launch height and a modest positive aim angle. Measure final minus initial ray angle and determine when the ray strikes the surface. An actual superior mirage can require more elaborate atmospheric layers and may produce multiple images; this simplified experiment isolates its fundamental curvature mechanism.

06 / Experiment III: the thermal duct

In Duct mode the cold centre is at z₀, and warmer surrounding air is modelled by T(z) = Tₐ − 0.0065z + ΔT[1 − exp(−((z−z₀)/H)²)]. Because n has a maximum near the cool centre, oblique rays feel restoring curvature. Start the source near z₀. Vary launch angle and count repeated upper and lower turning points. Hypothesis: a very steep launch angle escapes even a strong duct. Our channel is an idealised local temperature structure, not a prediction that real outdoor air commonly forms such symmetric ducts.

07 / Experiment IV: wavelength splitting

In Chromatic Split mode the renderer integrates three independent colours at 450, 550 and 650 nm through the same thermal profile. Dispersion means their phase indices differ slightly, even though the temperature field is shared. Examine the separate colourful bundles while adjusting the thermal contrast. Unlike a prism, air has a tiny index contrast, so a measurable split needs long distances and grazing geometry. The interface exaggerates vertical spatial dimensions, but does not multiply the integrated physical deflection.

08 / Experiment V: receiver alignment

The receiver mode asks an inverse question: given an atmospheric profile and source, which launch direction makes the ray reach a detector at a prescribed height and horizontal distance? Shift the receiver position or use the source-angle slider to reduce the signed miss. A zero crossing is not guaranteed: rays can hit the ground before the station. In survey engineering, related ideas appear in precision levelling, long-baseline optical alignment, and interpreting apparent horizon position during steep temperature gradients.

09 / Suggested research programme

First, measure the refractivity at two heights and estimate the gradient. Second, compare equal-magnitude hot and cold contrasts and record the sign of the angular curvature. Third, hold all parameters fixed except H and discover whether the turning point rises or disappears. Fourth, save wavelength-separated paths and ask which colour bends most strongly; explain it using the standard-air dispersion formula. Finally, try a long-range receiver alignment, record the thermal state and repeat after raising ambient temperature. For a quantitative report, use the CSV rather than estimating a tiny height from the spatially exaggerated 3D view.

10 / Assumptions and uncertainty

The air is flat, horizontally uniform, dry and stationary, with one-dimensional prescribed temperature. Pressure decays exponentially with a fixed 8400 m scale height rather than following self-consistent hydrostatic integration of the selected temperature profile. Earth curvature, turbulence, humidity, scattering, finite apertures, diffraction, solar heating dynamics, heat transport and true image formation are excluded. The wavelength formula estimates phase rather than group refractivity; the displayed optical traversal time is therefore a phase-optical-path proxy, not a broadband pulse delay. Ray trajectories are accurate within this idealised model, not observational predictions for a particular day. Numerical error is checked against the analytic stratified-medium invariant. The 3D geometry uses intentionally exaggerated vertical scale for readability.

11 / Glossary & questions

Refractive index n: ratio of vacuum phase speed to phase velocity. Refractivity N: one million times n−1. Gradient: spatial rate of change. Ray: local direction of geometrical energy propagation in the isotropic model. Turning point: where a ray’s vertical slope changes sign. Optical path length: ∫n ds. Duct: a profile that can bend some rays back toward a guiding layer. Caustic: an envelope where neighbouring rays concentrate. Further questions: What if pressure is calculated self-consistently? When would wave optics become necessary? Could several distant objects share a false apparent altitude?

VAPORLINE / FIELD MANUAL · MODEL 1.0Reference: laboratory equations and external reading in README.md
Made with 🤖 ChatGPT · Three.js