MYSIMULATOR.UK / OPTICS COLLECTION

TALBOT ATLAS

LAB ID 25B4-DDAB
INITIALISING
EXPERIMENTAL PHYSICS / DIFFRACTION ENGINEERING

Where light makes
copies of itself.

Manipulate a real Fourier-wave model on a precision optical bench. Move the detector through hidden self-images, design gratings and break coherence.

REVIVAL DISTANCE—2d² / λ · paraxial model
OPTICAL BENCH / LIVE INSTRUMENT

Talbot carpet

SCIENTIFIC FIELD RENDER · MONOCHROMATIC
DRAG TO ORBIT · SHIFT+DRAG TO PAN · WHEEL TO ZOOM · DRAG DETECTOR
WAVEFRONT / 2026
REAL-TIME WAVEFIELD ANALYTICS

Measured optical response

Click either graph to position its probe

Visibility = (Imax−Imin)/(Imax+Imin); correlation compares detector intensity with the near-grating reference. Angular spread is an incoherent 7-angle Gaussian quadrature; numerical Fourier truncation is disclosed in the guide.

SCIENTIFIC RECORD

Field notebook

Record live experimental measurements, then compare changes in wavelength, spatial coherence and transmission design.

Modeλ (nm)z/zTVisibilityCorrelation
No observations yet. Choose Record to capture a real calculated state.
0 recorded observations · data is held in this session
SELF-GUIDED LEARNING

Research challenges

0 / 10
QUANTITATIVE TASK

AN INTEGRATED SCIENTIFIC FIELD GUIDE

The physics behind the patterns

8 chapters · model-driven examples

01 / An image appearing out of nowhere

Illuminate a finely ruled transparent mask with a monochromatic plane wave. Close to the mask, its pattern of transmitted light is not simply blurred by diffraction. At carefully spaced propagation distances the pattern reconstructs itself. This is the Talbot effect, a near-field self-imaging phenomenon first reported by Henry Fox Talbot in 1836. Here a single-dimensional periodic grating sits in front of a movable, spatially resolved detector. The luminous horizontal map is an x–z intensity carpet: one transverse coordinate and the distance from the grating. It is not a photograph of a three-dimensional light volume.

02 / Operating the observatory

Select any of the five experiment tabs, then tune the calibrated controls. Drag in the 3D bench to orbit the camera, use the mouse wheel or a trackpad to zoom, and Shift-drag (or right-drag) to pan. The standing detector can also be dragged along the bench, changing its physical axial position; the position slider is an accessible precision alternative. Double-click or press Home to restore the camera. Start the detector scan with Play, stop with Pause, or choose a preset that reconfigures the apparatus. Record measurements in the notebook and export comma-separated values to process elsewhere. Click the screen-profile graph to position a transverse sampling probe; click the axial graph to move the detector. Both probes read the real computed optical field.

03 / The complex-field propagation model

The grating transmission is represented by a spatial Fourier series: t(x)=Σ cₘ exp(i 2πmx/d), where d is the grating pitch, m is an integer spatial harmonic, and cₘ is its complex amplitude. Under the paraxial Fresnel approximation the propagated field, apart from a common carrier phase, is E(x,z)=Σ cₘ exp[i 2πmx/d − i πλzm²/d²]. The measured intensity is I(x,z)=|E(x,z)|², normalised to unit incident plane-wave intensity. No random data points are used. The model retains 53 Fourier harmonics, from −26 through +26, and directly calculates the two displayed graphs.

04 / Mapping a Talbot carpet

In Talbot Carpet mode, change the period or the wavelength and watch the axial pattern rescale. Since each harmonic acquires a phase proportional to m², all harmonics rephase at zT=2d²/λ. The first full revival occurs one Talbot length from the mask; a later one occurs at twice that distance. Try doubling the pitch without changing wavelength. Predict a fourfold increase in the absolute revival distance, even though the on-screen longitudinal axis is expressed in units of the new Talbot distance. The detector readout in millimetres allows quantitative comparison.

05 / Fractional revivals

Switch to Fractional Images. At half a Talbot distance, exp(−iπm²)= (−1)ᵐ, so the field has shifted laterally by half a period. The shifted intensity is real physics, not a detector graphic trick. Set the screen successively to 0, 0.5, and 1 Talbot lengths. Watch the correlation with the unshifted entrance image switch from positive to negative (depending on duty cycle), then return toward +1. Quarter-distance planes display richer fractional replicas. A finite Fourier truncation softens the sharp edges of a binary amplitude mask.

06 / Grating materials and spectral mixing

In Grating Workshop, compare binary amplitude transmission (light passed or blocked according to open-area fraction f) with a sinusoidal phase grating t(x)=exp[iφ cos(2πx/d)]. The latter only modifies phase at the entrance: its total mean intensity approaches one, rather than the duty fraction. Fourier coefficients of the phase mask are numerically integrated across 2,048 periodic samples. In Chromatic Mixer, choose a second wavelength and its power fraction w. Since the colours are mutually incoherent, the recorded signal is (1−w)Iλ₁+wIλ₂. Their individual Talbot distances differ, producing distinct superposed revival structures. The display is a false-colour intensity visualisation; it does not reproduce human colour perception.

07 / Coherence, instruments and real applications

In Coherence Lab an angularly extended source illuminates the mask. Each incidence angle shifts its pattern transversely by approximately zθ. A seven-node, Gaussian-weighted incoherent angular average models the finite source width: larger angular spread increasingly smears the fine-scale revivals with propagation distance. Compare visibility with the same incident wavelength but a point-like source. Self-imaging informs lithography, grating-based metrology, X-ray phase-contrast imaging, Talbot–Lau interferometry and structured optical illumination. In engineering, limited source coherence or spectral bandwidth can be either a problem to suppress or a mechanism to design for.

08 / Assumptions, boundaries and next questions

This is scalar, monochromatic-per-channel, one-dimensional, paraxial Fresnel propagation in homogeneous free space. It assumes an infinite periodic mask, normal incidence for the default source, unit incident amplitude, no polarisation, absorption except the opaque amplitude bars, and negligible multiple scattering. Chromatic beams are added as intensities, never as coherent fields. Angular spread uses seven quadrature angles and a small-angle shift. Diffraction is sampled on finite periodic x–z grids; sharp edges show Fourier ringing and grid discretisation. There is no finite aperture envelope, near-contact evanescent field, or quantitative photo-detector noise. Consequently the picture is credible for wavelengths much smaller than pitch and propagation in the paraxial regime, not for nanometre gratings, high-angle vector diffraction, or microscope-limited apertures. Further questions: Why does the period-square law appear? What changes for a two-dimensional lattice? Can a fractional revival act as an optical beam splitter? How does source size set the useful imaging range?

Made with 🤖 ChatGPT · Three.js