MYSIMULATOR / OPTICAL PHYSICS COLLECTION

GYROPHASE / OBSERVATORY

NUMERICAL MODEL ONLINEEXPERIMENT 01—06SEED 0x98FB20713456003C
LAB / 007WEIGHING ROTATION WITH LIGHTA rotating reference frame makes two otherwise identical journeys end at different times.
Δφ = 8πNAΩ / λc
OPTICAL BENCH / THREE-DIMENSIONAL VIEW
RENDERER
OPTICAL PATH / CW ●
CCW ●
ROTATION FRAME / LABORATORY COORDINATES t = 0.00 s
LIVE TRACE / AINTERFERENCE
Click a curve to sweep the experiment
LIVE TRACE / BPHASE RESPONSE
Directly computed from the scientific model
03 / EXPERIMENTAL JOURNAL

Field notebook 00

Pin experimental conditions and compare quantitative phase predictions. Entries are kept in this browser.

#ExperimentR / mNΩ / rad·s⁻¹Δφ / radA / %Visibilityt / s
No readings captured yet. Press “Record measurement” to start.
04 / ACTIVE LEARNING

Physics challenges 00 / 10

Ten automatically checked calculations based on your current experiment settings.

05 / THE SCIENCE

Field guide to rotating light

01

Two beams. One loop. A moving meeting point.

Send two optical waves around the same closed path in opposite directions. When the optical apparatus rotates, they return at slightly different times. Their recombination creates a phase difference that reveals angular velocity without a spinning mechanical gyro rotor. This is the Sagnac effect, fundamental to ring-laser and fiber-optic gyroscopes.

01 / Operating the observatory

Select an experiment from the six stations at the top. Modify numeric sliders; the apparatus, detector fractions, phase indicator and both graphs all update from the same model. Drag the golden ring handle to alter radius. In the Earth experiment drag the green gimbal vector to reorient the sensor. Drag empty space to orbit, shift-drag to pan, and scroll or pinch to zoom. The play control animates the platform and deliberately slowed light markers; numerical phase is evaluated from the specified angular rate, not inferred from marker animation. Use Reset Time or Restore Preset to repeat an observation.

02 / Fundamental equation

A circular path of radius r encloses area A = πr². At ordinary laboratory velocities the counter-propagating time difference is Δt = 4NAΩ/c², where N is the number of turns, Ω the signed angular-rate component normal to the loop, and c the speed of light in vacuum. The interferometric phase is Δφ = 2πcΔt/λ = 8πNAΩ/(λc) for vacuum wavelength λ. The phase scale factor K = 8πNA/(λc) turns a measured phase into an angular rate.

03 / Vacuum ring: a relativistic clock

Begin with one circular vacuum loop. Increase the rotation speed and notice how the phase changes sign when direction reverses. The rotating detector meets the two rays after unequal coordinate travel times. In this station an exact special-relativistic receiver-clock correction multiplies the low-speed answer by 1/√(1−(Ωr/c)²). All available control values are vastly below the relativistic limit; the correction is tiny but included. Hypothesis: at fixed speed, doubling loop radius quadruples phase.

04 / Fiber coil: multiplying sensitivity

A fiber-optic gyroscope routes both beams through hundreds or thousands of turns of co-moving optical fiber. The leading-order Sagnac phase depends on enclosed area and turn count; it is independent of the fiber’s ordinary refractive index for a reciprocal, co-moving loop. Change the winding count and radius, then compare the two calculated traces. The 3D model displays a representative bundle rather than drawing every microscopic fiber turn. The length readout uses the real count L = 2πrN. Nonreciprocal thermal and mechanical errors, polarization drift and fiber loss are omitted.

05 / Earth vector: orientation matters

Earth rotates at approximately 7.2921150 × 10⁻⁵ rad/s. In a local east-north-up frame, its angular-velocity vector has north and vertical components ΩE cos(latitude) and ΩE sin(latitude). The projection onto a loop normal of azimuth a (clockwise from north) and elevation e is ΩE[cos(e)cos(a)cos(latitude) + sin(e)sin(latitude)]. Align the coil toward geographic north near the horizon, then vertically. East-pointing horizontal normals measure zero Earth rotation in this idealised model.

06 / Balanced ports: converting phase to signal

An ideal 50:50 recombiner produces complementary normalized outputs pA = [1+V cos(Δφ+φbias+φimb)]/2 and pB = 1−pA, with visibility V. Set bias near 90° to operate at quadrature, where small phase shifts give the strongest linear intensity response. Set bias near 0° and inspect the lower slope at a bright or dark fringe. These are photon fractions for ideal lossless ports, not calibrated optical watts. The contrast control accounts for imperfect optics without claiming any measured performance.

07 / Coherence bench: finite bandwidth

Real sources have nonzero spectral linewidth. The bench uses a Gaussian spectral power distribution, a narrow-band conversion Δν ≈ cΔλ/λ², and an intentionally adjustable extra path imbalance ΔL. The predicted visibility is V = V₀ exp[−(πΔνΔL/c)²/(4 ln 2)] where Δλ is the full width at half maximum. Larger mismatch and broader linewidth wash out contrast. The extra path also contributes 2πΔL/λ to the interference phase. The model assumes smooth Gaussian spectra and ignores chromatic dispersion and polarization mismatch.

08 / Photon metrology: the quantum limit

In the last station, choose a photon count and take a sample. Each detection is modeled as an independent Bernoulli trial with success probability pA. The expected fraction variance is pA(1−pA)/Nphotons. Small samples are generated from exact Bernoulli draws; for counts above 100,000 the app uses a stated Gaussian approximation to the binomial distribution. The uncertainty in inferred rotation is the fraction uncertainty divided by the absolute local response slope. Very near an interference maximum or minimum the slope vanishes and linearized uncertainty is undefined: choose quadrature instead.

09 / Real-world uses & boundaries

Sagnac instruments support inertial navigation, aircraft and marine attitude sensing, industrial motion control, geodesy and rotation seismology. This laboratory models a uniform circular optical path; it does not solve Maxwell’s equations in dispersive fiber or simulate closed-loop control electronics. It assumes steady angular velocity, a common-mode reciprocal medium, an ideal balanced recombiner, and no temperature drift. The vacuum station includes an exact rigid-ring correction; all multi-turn fiber stations use the low-speed Sagnac relation. Photon noise is statistical Monte Carlo, not a prediction of a particular commercial detector.

10 / Suggested investigations

Area scaling: measure phase at two radii with identical speed and turn count; compare the squared-radius law. Rate reversal: record opposite angular velocities and inspect signed phase and complementary outputs. Compass experiment: sweep Earth-mode azimuth at fixed elevation and find zero projection. Visibility test: change spectral FWHM and match predicted coherence decay. Precision test: increase photon count by a factor of 100 at quadrature and check that statistical uncertainty falls by a factor of ten.

Glossary & next questions

Reciprocity: identical optical response for waves traversing the same path in opposite directions. Phase: angular location in an oscillation, measured in radians. Visibility: normalized fringe contrast. Quadrature: operating phase with maximal local slope. Shot noise: variance arising from discrete detection events. Scale factor: phase response per unit rotation. What changes when loop area is not planar? How should one separate Earth rotation from platform rotation? Why do polarization and thermally induced nonreciprocal phase shifts matter in real fiber gyros?

Made with 🤖 ChatGPT · Three.js