Presets
Playback
Parameters
Camera
Layers
Quality
Model check
The science
What is modelled
A step-index multimode fibre: a glass core (index n1) inside a cladding (index n2 < n1), a straight lead, a circular bend of radius R and angle Φ, and a straight exit lead. Light is followed as exact geometric rays in the plane of the bend. The picture magnifies a real 50 µm core about a thousand times; every result depends only on ratios, so the physics is scale-free.
Equations
- Snell:
n1 sinφ = n2 sinψ, φ measured from the wall normal. Total internal reflection whenn1 sinφ ≥ n2, i.e. beyond the critical angleφc = asin(n2/n1). - Below φc the wall still reflects the Fresnel fraction (mean of s and p):
Rs = ((n1cosφ − n2cosψ)/(n1cosφ + n2cosψ))²,Rp = ((n1cosψ − n2cosφ)/(n1cosψ + n2cosφ))²; the rest escapes into the cladding (orange sparks). - Numerical aperture
NA = √(n1² − n2²); acceptance half-angle in airasin(NA)(a straight fibre guides every ray inside it). - Bend: a straight ray keeps its distance from the bend centre. A ray entering at offset q with angle θ has
d = (R + q) cosθand meets the outer wall atsinφ = d/(R + a), so it is guided only if(R + q) cosθ ≥ (R + a) n2/n1. For the axial ray this gives the minimum radiusRmin = a n2/(n1 − n2)(graph 1, cyan line). - Throughput is the mean remaining power of 210 rays from a Lambertian 2-D source (sinθ uniform) with the chosen half-angle in air, refracted into the core by
sinθcore = sinθair/n1. The three graphs re-run that ensemble for every point.
Checks run in the page
- The ray tracer finds the guided/leaky boundary angle by bisection; it must equal asin(n2/n1).
- The tracer finds the smallest bend radius that keeps the axial ray in a 90° bend; it must equal a n2/(n1 − n2).
- For 2000 random rays entering a bend the first outer-wall incidence angle must match asin(d/(R + a)); plus Fresnel at normal incidence.
Honest simplifications
Meridional rays only (skew rays and mode structure of a real multimode fibre are ignored, as is wave optics: a 50 µm core carries hundreds of modes, a single-mode fibre needs the wave picture). No absorption or scattering along the length, no Fresnel loss at the end faces, and light that reaches the cladding is treated as lost (a real cladding is bounded by a coating that absorbs it, though a little can re-enter the core). The index values are round numbers, not those of one product.
What to try
- Lower the bend radius below Rmin with a narrow source (0°): the axial ray starts to leak, then the whole fan.
- Raise n2 towards n1: NA collapses and the acceptance cone closes (graph 2).
- Raise the source half-angle past asin(NA) in a straight fibre: throughput falls (graph 3).
- Use the Detector camera to read the power on the receiver screen.