The science
Point kinetics. Neutron population n (relative to full power) and six delayed-neutron precursor groups Ci obey
dn/dt = (ρ - β)/Λ · n + Σ λi Ci
dCi/dt = (βi/Λ) n - λi Ci
β = 650 pcm is the delayed fraction of U-235 (Keepin's six groups, mean lives from 0.3 s to 81 s), Λ = 20 µs the prompt generation time. Delayed neutrons are only 0.65 % of all fission neutrons, but they arrive seconds late and set the time scale: a reactor with ρ below β changes power on a period of seconds to minutes instead of microseconds. For a small step the stable period is the root of the inhour equation ρ = Λω + Σ βiω/(ω+λi); the page checks its integrator against it. Reactivity ρ = (k-1)/k is quoted in pcm (10-5).
Reactivity budget. ρ = ρexcess - Wrods(z) - 8 pcm/ppm × boron - WXe + αD(Tfuel-T0) + αM(Tcool-T0). Rod worth follows the S-curve of a chopped-cosine flux, W(z) = Wtot[z - sin(2πz)/(2π)], so rods matter most in the middle of the core. Both temperature coefficients are negative (Doppler -2.5 pcm/K, moderator -20 pcm/K): a power rise heats the core and pushes reactivity down, which is why the reactor settles instead of running away.
Xenon-135. Iodine-135 (6.6 h half-life) decays into xenon-135 (9.1 h), a very strong neutron absorber (2.6 million barn). dI/dt = γIΣfφ - λII and dX/dt = γXΣfφ + λII - λXX - σXφX. After a trip the flux burn-out stops while iodine keeps feeding xenon, so xenon peaks at about 1.9 x its full-power value roughly 8 h later (the xenon pit), and a restart may be impossible until it decays. The page compares this with the closed-form solution.
Heat. Three exponential groups reproduce decay heat (about 6.6 % of rated power when the reactor stops, 1 % after an hour). Fuel and coolant are two lumped heat capacities exchanging heat; the steam generator is assumed to hold the inlet temperature at 292 C, and the pressurizer holds 155 bar (saturation 344.8 C), giving the subcooling margin.
Simplifications. Zero-dimensional: no spatial flux shape, no axial xenon oscillations, no burnup or fuel depletion, no boiling or void feedback, fixed inlet temperature, one lumped coolant node, rod speed 1 %/s (real plants about 0.5 %/s), idealised turbine (34 % efficiency, speed follows power). All coefficients are typical textbook values for a generic 3000 MWth PWR, not a specific plant, and rated power is shown as an illustration. This is an educational model of reactor physics; it contains no weapon-related content and must not be used for plant operation.