Nuclear Reactor Core Glow (2D)

Six-group point-kinetics model of a generic thermal reactor: rods, delayed neutrons, temperature feedback, decay heat and the blue Cherenkov glow of a water pool. Educational physics of a power reactor.

Live readouts

Numerical checks

  • running...
The science

Point kinetics. Neutron population n (relative power) obeys dn/dt = ((ρ−β)/Λ) n + Σ λiCi + S and six delayed-neutron precursor groups dCi/dt = (βi/Λ) n − λiCi (U-235 thermal data, total β = 0.0065, prompt generation time Λ = 0.1 ms). Because about 0.65 % of neutrons arrive seconds late, a reactor with ρ < β changes power on a period of tens of seconds rather than milliseconds - that is what makes control possible. Above ρ = β (one "dollar") the chain reaction no longer needs delayed neutrons ("prompt critical") and power can rise in milliseconds, which is why real rods are withdrawn slowly (here at most 2 % of travel per second) and why a shutdown (SCRAM) inserts them quickly.

Reactivity. ρ = Rtot[g(w)−g(wc)] + αf(Tf−900 K) + αc(Tc−580 K). The rod worth integral g(w) = w − sin(2πw)/(2π) is the standard S-curve for a cosine flux (rods matter most mid-core). The Doppler fuel coefficient αf and the moderator coefficient αc are negative: more power heats fuel and water, which lowers ρ and pushes power back. This self-regulation is why the power settles instead of running away.

Heat. Fuel and coolant are two lumped heat capacities, Cf dTf/dt = Q − h(Tf−Tc), Cc dTc/dt = h(Tf−Tc) − G(Tc−Tin), with the removal term scaled by the coolant-flow slider. Heat Q = 0.935 n + H, where H is decay heat from fission products (two exponential groups, 3.5 % with 30 s and 3 % with 2000 s lifetime, 6.5 % of full power in total, roughly the textbook value just after shutdown). It keeps the fuel hot after a SCRAM and is why cooling must continue.

Cherenkov glow. Charged particles faster than light in water (phase speed c/n, n = 1.333) emit a cone of blue light of half-angle cos θ = 1/(nβ), with a threshold electron kinetic energy of 0.264 MeV. The Frank-Tamm yield is dN/dx = 2πα sin²θ (1/λ1 − 1/λ2), about 200 photons per cm in 400-700 nm for a fast electron. The glow brightness drawn here follows the total radioactivity, so it fades after shutdown as decay heat falls, not instantly.

Honest simplifications. A generic one-region model, not any specific plant: no xenon, no spatial flux shape or void feedback, no boiling, constant parameters, lumped (not radial) temperatures, a slow-motion scale selectable up to 500x. Coefficients are plausible orders of magnitude, not design data. The numerical checks below the controls compare the simulation to the inhour equation, to steady-state, to energy conservation and to Frank-Tamm.