A vibratory MEMS/NEMS gyroscope suspends a proof mass on flexures that behave as two independent spring–mass–damper oscillators along orthogonal axes: a drive mode (x) that is electrostatically shaken at its own resonance, and a sense mode (y) that is normally silent.
Drive: m x'' + c_x x' + k_x x = F0 cos(ω t)
Sense: m y'' + c_y y' + k_y y = -2 m Ω x'
When the whole chip rotates about the axis normal to the plane at angular rate Ω, the Coriolis pseudo-force -2mΩẋ pumps energy from the moving drive mass straight into the sense mode — with zero rotation there is no coupling term and y stays at rest. Solving both linear oscillators for a sinusoidal drive at frequency ω gives closed-form complex amplitudes:
X(ω) = F0 / (k_x − mω² + iωc_x)
Y(ω) = −2mΩ·(iωX) / (k_y − mω² + iωc_y)
This simulator evaluates that frequency response exactly, every frame — no drift, no integrator instability. The drive frequency slider sweeps ω across the drive resonance, tracing out the classic Lorentzian amplitude peak. The mode mismatch Δf = fy − fx sets how far the sense spring's own resonance sits from the drive frequency: as Δf → 0 ("mode-matched") the sense mode sits on its own resonance peak too, and the Coriolis signal is amplified by roughly the sense-mode quality factor Qy — real gyros trade this huge sensitivity gain against a much narrower bandwidth and higher sensitivity to fabrication tolerances and temperature drift, which is why many designs deliberately mismatch the modes by tens of Hz and rely on higher drive amplitude instead.
- Drive frequency offset — detunes the electrostatic drive away from the mass's natural frequency fx, shrinking the drive amplitude and shifting its phase.
- Rotation rate Ω — the quantity being measured; the sense amplitude scales linearly with it (that linear scale factor is the sensor's calibration constant).
- Mode mismatch Δf — the frequency gap between the two mechanical resonances; the "Mode-match" button drives it to zero to show the resonant amplification.
- Sense-mode Qy — set by damping (squeeze-film gas damping, anchor loss, thermoelastic loss); higher Q under vacuum packaging sharpens and raises the resonance peak.
The teal trail traces the combined x–y motion of the proof mass — with Ω = 0 it is a straight line along the drive axis; any rotation bends it into an ellipse (a Lissajous-like figure) whose minor-axis width is the sense signal.