Geometry, coupling gap and waveguide loss of the resonator.
Analyte
Index change in the solution above the ring.
Read-out
Noise on the measured resonance wavelength.
Camera
Quality
Layers
Model checks
The science
The all-pass ring
Light in a bus waveguide couples into a ring of circumference L = 2 pi R. With field self-coupling t = sqrt(1 - kappa^2) and single-pass amplitude a = 10^(-loss L / 20) the transmitted power is T = (a^2 - 2 a t cos(phi) + t^2) / (1 - 2 a t cos(phi) + a^2 t^2) with round-trip phase phi = 2 pi n_eff(lambda) L / lambda. Resonances (dips) sit where phi is a multiple of 2 pi; the dip bottom is ((t - a) / (1 - t a))^2 and is zero at critical coupling t = a.
Spacing, linewidth and Q
The free spectral range is FSR = lambda^2 / (n_g L), the group index n_g accounting for dispersion. The exact full width at half depth in phase is 4 asin(1 / sqrt(F)) with F = 4 t a / (1 - t a)^2, which gives the wavelength FWHM and Q = lambda / FWHM. Small coupling and low loss give narrow, high-Q lines.
Sensing
The evanescent tail of the mode samples the cladding. A refractive-index change dn there changes the effective index by Gamma dn (here Gamma = 0.2), shifting a resonance by d lambda = lambda Gamma dn / n_g, about 74 nm per refractive-index unit. A detector reading the resonance position with noise sigma can resolve dn = 3 sigma / S. The shift develops with a first-order time constant as analyte reaches the surface.
Simplifications
One polarisation, constant Gamma and group index, a bus-ring coupler with no excess loss or dispersion, perfectly smooth sidewalls (real rings have backscatter and resonance splitting), no thermal drift, and a simple Gaussian noise model; the analyte is a bulk index change and binding is shown as a count of molecules on the ring.
What to try
- Press "Critically coupled": the dip deepens towards zero transmission (dip depth above 30 dB in an ideal ring).
- Raise the loss or the coupling and watch the dip become shallower and wider while Q falls.
- Choose "High-Q ring": the linewidth drops to a few picometres and the same shift is much easier to read above the noise.
- Increase the radius: resonances crowd together (smaller free spectral range) while Q grows.
- With an analyte present, the transmission at the fixed laser wavelength changes strongly because the dip has moved away from it.