Silicon Microring Sensor

Resonance dip, Q factor and refractive-index sensing.

Switch to 2D

Presets

Playback

Ring

Geometry, coupling gap and waveguide loss of the resonator.

Analyte

Index change in the solution above the ring.

Read-out

Noise on the measured resonance wavelength.

Camera

Quality

Layers

Model checks

The science

The all-pass ring

Light in a bus waveguide couples into a ring of circumference L = 2 pi R. With field self-coupling t = sqrt(1 - kappa^2) and single-pass amplitude a = 10^(-loss L / 20) the transmitted power is T = (a^2 - 2 a t cos(phi) + t^2) / (1 - 2 a t cos(phi) + a^2 t^2) with round-trip phase phi = 2 pi n_eff(lambda) L / lambda. Resonances (dips) sit where phi is a multiple of 2 pi; the dip bottom is ((t - a) / (1 - t a))^2 and is zero at critical coupling t = a.

Spacing, linewidth and Q

The free spectral range is FSR = lambda^2 / (n_g L), the group index n_g accounting for dispersion. The exact full width at half depth in phase is 4 asin(1 / sqrt(F)) with F = 4 t a / (1 - t a)^2, which gives the wavelength FWHM and Q = lambda / FWHM. Small coupling and low loss give narrow, high-Q lines.

Sensing

The evanescent tail of the mode samples the cladding. A refractive-index change dn there changes the effective index by Gamma dn (here Gamma = 0.2), shifting a resonance by d lambda = lambda Gamma dn / n_g, about 74 nm per refractive-index unit. A detector reading the resonance position with noise sigma can resolve dn = 3 sigma / S. The shift develops with a first-order time constant as analyte reaches the surface.

Simplifications

One polarisation, constant Gamma and group index, a bus-ring coupler with no excess loss or dispersion, perfectly smooth sidewalls (real rings have backscatter and resonance splitting), no thermal drift, and a simple Gaussian noise model; the analyte is a bulk index change and binding is shown as a count of molecules on the ring.

What to try
  1. Press "Critically coupled": the dip deepens towards zero transmission (dip depth above 30 dB in an ideal ring).
  2. Raise the loss or the coupling and watch the dip become shallower and wider while Q falls.
  3. Choose "High-Q ring": the linewidth drops to a few picometres and the same shift is much easier to read above the noise.
  4. Increase the radius: resonances crowd together (smaller free spectral range) while Q grows.
  5. With an analyte present, the transmission at the fixed laser wavelength changes strongly because the dip has moved away from it.
Loading Blender model...
Transmission spectrum around one resonance
Resonance shift against time (noisy read-out)
Quality factor against ring radius
Dip depth against coupling: critical coupling peak
Made with 🟠 Blender · Three.js