Electric separation
DNA's phosphate backbone has negative charge. In an electric field it moves towards the positive electrode. Agarose acts as a porous sieve; smaller DNA fragments generally move further in a given time.
DNA ELECTROPHORESIS LABORATORY
Turn a transparent block of agarose into a molecular ruler. Load DNA, power the electrodes, and uncover the sizes hiding inside an unknown sample.
The known ladder builds a straight-line standard curve. Drag the probe to read the DNA size at any distance.
Measurements are from an idealised model. Real gels require loading controls, suitable standards and experimental calibration.
Every set contains 10 automatically marked questions and instrument challenges.
DNA's phosphate backbone has negative charge. In an electric field it moves towards the positive electrode. Agarose acts as a porous sieve; smaller DNA fragments generally move further in a given time.
For a given gel, we approximate migration speed as v = (V/100) × C−0.65 × [a(C) − b(C) log₁₀(L)] cm/min, where L is fragment length in bp, C is agarose percentage, a = 0.170 + 0.002(C − 1) and b = 0.030 + 0.006(C − 1). Distance d = vt. This is an illustrative local fit, not a universal material law.
Plot log₁₀(bp) = α + βd using the visible ladder bands. Use the fitted line to estimate unknown fragment lengths. Bands that leave the gel are excluded. Do not extrapolate far beyond the ladder's size range.
Gel electrophoresis is used to inspect PCR products, restriction digests and DNA samples in molecular biology. Real band appearance also depends on DNA mass, gel chemistry, buffer, temperature, voltage and sample preparation.