Controls
Presets
Parameters
Quality
Camera
Model checks
The science
Gap junctions. Neighbouring cells are joined by plaques of connexon channels (two connexin hemichannels docked end to end). Each pore passes ions and small metabolites (up to about 1 kDa, depending on the connexin isoform) but not larger molecules; gating by pH, Ca2+ or voltage changes the open probability Po. A dye or second messenger injected into one cell therefore spreads through the tissue like heat through a lattice.
Model. On a hexagonal lattice of 91 cells every shared edge has conductance g = g0 · (density) · Po · Φ(λ), where the size filter is the Renkin hindrance Φ(λ) = (1-λ)2(1 - 2.104λ + 2.09λ3 - 0.95λ5), λ = r/R (tracer Stokes radius over pore radius; r = 0.0515 MW0.4 nm is an empirical fit). Each cell obeys dci/dt = g Σj(cj - ci) - k ci with the centre cell clamped at 1. Along a line the steady profile is geometric, cn = ρn with ρ + 1/ρ = 2 + k/g, so the length constant is 1/acosh(1 + k/2g) cells; blocking the channels (Po → 0) or using a tracer above the cutoff isolates the cell.
Simplifications. Isotropic constant conductance, no voltage coupling (electrical synapses), no rectification, no extracellular leak, lumped cytoplasm (each cell one compartment), tracer is passive and inert. g0 is illustrative. Checks: the Renkin function against a hand value and limits; a 120-cell chain solved by a tridiagonal solver against ρn; time integration versus the steady-state solver together with the global balance (loss = flux out of the clamp); and a random-walk tracer ensemble whose mean-square displacement must equal 6 g a2 t.