Presets
Playback
Parameters
Camera
Layers
Quality
Model check
The science
What is modelled
The liver is built from hexagonal lobules. Blood enters at the six portal triads in the corners, flows inward through the sinusoids past the hepatocytes, and leaves through the central vein. Oxygen is used up on the way, so cells near the central vein live in low oxygen, while a Wnt/beta-catenin signal made around the central vein switches on a different set of genes there. This page follows both gradients, shows the three metabolic zones that result, and lets an acetaminophen overdose show why the damage starts in zone 3. The lobule is drawn 50 times larger than real (1 cm in the model = 50 µm) and the sinusoids are shown as straight radial lanes.
Equations
- Oxygen along a sinusoid (position s from 0 at the portal end to 1 at the central vein):
∂P/∂t + u ∂P/∂s = −k P / (Km + P), solved with an upwind scheme. In steady stateKm ln(P/P0) + (P − P0) = −κ swithκ = k/u, whose solution isP = Km W[(P0/Km) exp((P0 − κ s)/Km)](Lambert W). Slower flow lowers u and so raises κ. - Wnt signal:
∂W/∂t = D W'' − kd Wwith W fixed at the central vein and no flux at the portal end; steady stateW = W0 cosh(s/λ) / cosh(1/λ), λ = √(D/kd) = 0.5 of the lobule radius. - CYP2E1 follows the Wnt signal through a Hill function
C = W3/(K3 + W3). Zones: zone 1 where W < 0.35, zone 3 where W > 0.6, zone 2 between. - Acetaminophen is cleared with a 2.5 h half-life. Each hepatocyte makes the toxic metabolite NAPQI at
J = kN C A(t). Glutathione (G, normalised to 1) is refilled atks(1 − G)and conjugates NAPQI atJ G/(G + Kg); the remainderJ Kg/(G + Kg)binds proteins and adds to a damage counter, and a cell dies when the counter reaches 1. Oxygen below 15 mmHg adds hypoxic damage.
Checks run in the page
- The oxygen PDE after 200 s is compared with the Lambert-W closed form along the whole sinusoid.
- The Wnt solver started from zero reaches the cosh profile.
- NAPQI bookkeeping: NAPQI formed = glutathione conjugated + protein adducts, and the glutathione lost equals conjugated minus synthesised.
- Oxygen balance: inlet minus outlet equals the integrated uptake.
Simplifications
- Sinusoids are radial and independent; real sinusoids branch and join, flow is not uniform and blood oxygen is carried mostly on haemoglobin (lumped into the transit time and the effective Km). Oxygen and Wnt run on their own time scales: oxygen in seconds, Wnt and toxicity in hours.
- Rate constants, the Hill parameters and the dose scale (10 g = reference) are round illustrative numbers, not fitted to patient data; the 10 % cell-to-cell spread in CYP2E1 is invented to roughen the edge of the necrotic zone.
- Other pathways (sulfation, glucuronidation, mitochondrial injury, regeneration, immune response, the N-acetylcysteine antidote) are not modelled. Educational model, not for clinical decisions.