Pressure. The arteries are modelled as a two-element Windkessel: C dP/dt = Q(t) − P/R. The ventricle ejects a half-sine flow Q(t) during systole (duration ≈ 0.37√T); in diastole the pressure falls exponentially with time constant RC. The mean pressure is MAP = CO × R, so raising the vessel resistance raises blood pressure at the same cardiac output.
Cardiac output. CO = HR × SV. At high heart rates the filling time shrinks, so stroke volume falls (a simple square-root law around 70 mL at 72 bpm) and output rises less than the rate.
Oxygen. Haemoglobin saturation follows the Hill curve S = Pn/(Pn + P50n) with n = 2.7, P50 = 26.8 mmHg. Content CaO2 = 1.34·Hb·S + 0.0031·P. With a fixed resting uptake of 250 mL O2/min the Fick principle gives the venous content, so anaemia or a slow heart lowers venous saturation.
Simplifications: the real mean circulation time (blood volume 5 L divided by output) is about a minute, so the animated cells run several times faster than reality; the circuit is one lung loop and one body loop, with no separate organs, valves or venous reservoir; resistance is a single lumped value; the heart-rate dependence of stroke volume and the 93 mmHg reference pressure are textbook-typical, not patient data. Educational, not diagnostic.