Trauma Response Time Lab: Venous Return, Oxygen Delivery and Oxygen Debt (2D)

A side view of a training bay: change how fast the simulated loss is controlled and when fluid starts, and follow pressure, cardiac output, oxygen delivery and oxygen debt on the clock.

Switch to 3D
Controls

Presets

Parameters

Model checks

The science

What the page models. An abstract adult training mannequin loses simulated circulating volume at a set rate until the loss is controlled, and may receive isotonic fluid. The question is how fast tissues run short of oxygen, which depends on cardiac output, not on pressure alone. Cardiac output is the operating point of the Guyton diagram: venous return VR = (Pms − Pra)/Rv falls with right-atrial pressure, cardiac function CF = COpl(1 − e−Pra/k) rises with it, and the two curves cross where the heart delivers exactly what returns to it.

Blood loss shifts the venous-return line. The mean systemic filling pressure Pms is the pressure in a stopped circulation; it is proportional to the stressed volume, Pms = 7 mmHg × (V − Vu)/(V0 − Vu) with the unstressed volume Vu = 70 % of V0. Losing 15 % of the blood removes about half of the stressed volume, which is why output drops so steeply. The body answers with a sympathetic reflex (first-order lag, 0.5 min): veins constrict (Vu shrinks), the heart contracts harder (CF plateau +40 %), the heart rate rises to 130 per minute at most and resistance rises 80 %, so the arterial pressure stays up longer than the flow does: MAP = CO · SVR + Pra.

Oxygen. CaO2 = 1.34 · Hb · SaO2 + 0.0031 · PaO2 (20 mL/dL for Hb 15 g/dL), DO2 = 10 · CO · CaO2 (about 1000 mL/min for 5 L/min) and the demand is 3.5 mL/kg/min. Tissues can extract at most about 70 % of the delivery, so once 0.7 DO2 < VO2 an oxygen debt accumulates (dD/dt = VO2 − 0.7 DO2) and is repaid only slowly afterwards. Infused crystalloid restores volume (here 30 % stays in the vessels) but dilutes the hemoglobin, so output recovers while oxygen content falls; the page shows that trade-off.

Numerical checks. The Guyton crossing is solved three independent ways (bisection, Newton, brute-force scan); the stepped volume is compared with the closed form; the textbook values CaO2 20, DO2 1000, extraction 25 % are reproduced; red-cell mass is conserved under pure infusion; the oxygen-debt integral converges under time-step refinement; class limits and the zero-pressure limit are tested.

Simplifications and safety. One lumped circulation (no regional flow, no heart-rate limit on filling, constant arterial oxygen saturation, no clotting, pain or anaesthesia), constant tissue demand, textbook round numbers. The class thresholds (15, 30, 40 % of blood volume) follow the commonly taught ATLS-style table; the O2-debt limit of 28 mL/kg is only an illustrative marker. This is an educational physiology model on an abstract training mannequin, not a clinical protocol and not medical advice. In a real emergency call your local emergency number.

-
-