The science
What is modelled
A 1 m nitinol (nickel-titanium) wire hangs from an insulated clamp and carries a weight. An electric current heats it (Joule heating). Cold, the wire is martensite: soft and easily stretched by the load. When it warms past the transformation range it becomes austenite, the crystal returns to its parent shape and the wire contracts, lifting the weight. On cooling the load stretches it again. The transformation temperatures depend on the stress in the wire, and heating and cooling follow different paths (hysteresis).
Equations
- Heat balance of the wire:
C dT/dt = I² R − h As (T − Ta) + m ΔH dξ/dt, withC = m c, surfaceAs = π d L, and the latent heatΔHabsorbed when the martensite fraction ξ falls and released when it rises. - Resistance
R = ρ(ξ) L / Awith a slightly higher resistivity in the austenite. - Transformation (cosine law of Liang and Rogers): heating
ξ = (ξ0/2) [cos(π (T − As)/(Af − As)) + 1], coolingξ = ((1−ξ0)/2) cos(π (T − Mf)/(Ms − Mf)) + (1+ξ0)/2. - Stress shifts the temperatures (Clausius-Clapeyron):
T′ = T + σ / CM, about 7 MPa per kelvin, withσ = m g / A. A heavier load needs a hotter wire to lift it. - Strain
ε = εtr ξ + σ / E(ξ)with 4 % transformation strain (reached when the load detwins the martensite) and a stiffer austenite (75 GPa against 28 GPa). - Steady state below the transformation:
T = Ta + I² R / (h As), time constantτ = C / (h As).
Checks run in the page
- The energy balance closes: electrical energy = stored heat + loss to air + latent term.
- Slow temperature ramps find the four transformation temperatures at the load stress equal to the stress-shifted formulas.
- Below the transformation the wire settles at the analytic steady temperature.
Honest simplifications
- Uniform temperature and stress along the wire, constant heat transfer coefficient, constant 7 MPa/K slope, an idealised cosine transformation with no minor-loop calibration, no fatigue or training, no R-phase, and a fixed 1 m length. The "temperature colour" is a false colour. The electrical-to-mechanical efficiency of such an actuator is well under 1 %, as the readout shows.
What to try
- Pulse the current and watch the load rise and fall with a delay: the hysteresis loop in the middle graph.
- Triple the load and see the transformation temperatures climb in the stress-temperature diagram.
- Switch to the fan cooling preset: the return stroke gets quicker, the wire needs more current to stay hot.
- Use the thermostat to hold the wire half transformed so the load stays in mid-position.