Trabecular (spongy) bone is a network of struts. Under an axial load F every strut is strained by ei = e cos²θi (affine rod network), and the load balance gives
e = F H / (Es S), S = Σ Aj Lj cos&sup4;θj, apparent modulus Eapp = Es S / V (Es = 10 GPa; units: 1 unit = 5 mm).
Each strut repeatedly runs a remodelling cycle: osteoclasts resorb, r → r e-aR, then osteoblasts form, r → r e+a Fe x, where x = e/e0 is the strain relative to the mechanical set point (Frost's mechanostat / Wolff's law). Setting the two equal gives the equilibrium x* = R/Fe, and because strain falls as 1/r² the density settles at
BV/TV* / BV/TV0 = (F/F0) (Fe/R).
The checks below compare the live stepper with this closed form, with the column and isotropic-network limits (Eapp = Es·BV/TV/5), and with the unchanged healthy state.
Simplifications: ~400 struts instead of the thousands in real bone (so each strut is thicker than real trabeculae), a Voigt (affine) stiffness estimate with no bending or buckling, uniform load, one global set point, cortical bone does not remodel here, and the cell cycle times are compressed for display. The set point and rates are illustrative, not patient data.
Running numerical checks...