R = 1 + ρᵦ Kd / n
v = K i / n; Dᴸ = αᴸ v + Dₘ; Dᵀ = αᵀ v + Dₘ
R ∂C/∂t = Dᴸ Cₓₓ + Dᵀ Cᵧᵧ − v Cₓ − R λ C
C = M R / (4π n b t √(DᴸDᵀ)) · exp[−(x−vt/R)²R/(4Dᴸt) − y²R/(4Dᵀt) − λt]
Linear equilibrium sorption is represented by the retardation factor R. The pulse is instantaneous and point-like; the aquifer is homogeneous, fully saturated, infinite in plan view and has uniform flow. Dispersion is constant, decay is first-order, and density-driven flow, source duration, heterogeneity and well-induced flow are omitted. Concentration is converted using 1 kg/m³ = 1,000 mg/L.
Value status: illustrative, scaled teaching parameters; equations are textbook idealisations.
Illustrative design, not affiliated with any real institution or manufacturer.