Fieldnotes / Fluid systems
Explore the 3D apparatus ↗
Engineering laboratory / 04. Hydraulic energy

Hydraulic ram pump

Lift a fraction of flowing water without external power. Explore the pressure surge, valve timing and air-chamber behaviour behind the cycle.

MODEL SEED · 593817
01 / System cutawayCycle running
Drive flowPressure surgeLifted waterAir cushion
02 / Live performanceSI units
Peak valve head
—
m water column
— kPa gauge
Delivered flow
—
L / s
— L per cycle
Hydraulic efficiency
—
output / input power
— W output
Drive velocity
—
m / s in drive pipe
— L/s inlet flow
Independent check pending
Valve pressure transient
Damped water-hammer response · first 8 round trips
Delivery pulse
Flow through the delivery check valve · one cycle
Lift envelope
Predicted delivery flow as delivery head increases

Operating conditions

Move a control to update the shared 2D / 3D scenario and its URL.

Live model
2.5 m
Available gravity head
16.0 m
Static lift to outlet
8.0 m
Wave travel distance
50 mm
Internal diameter
55 ms
Compared with 2L / a
7.0 L
Buffers delivery pulsation
1.15 Hz
Valve cycle rate
The science / equations and assumptions

A hydraulic ram uses the inertia of water in a drive pipe. When the waste valve closes quickly, the moving column is decelerated and a pressure wave briefly raises the pressure above the delivery head. A check valve admits a small volume into the air chamber and delivery line; the air cushion smooths the discharge.

v = √(2 g Hₛ / [1 + fᴅ L/D + K])   ·   Qᵢₙ = (πD²/4) v
Δp = ρ a Δv · min(1, 2L / (a t꜀) )   ·   ΔH = Δp / (ρg)
Qₒᵤₜ = η₀ (Hₛ / Hᴅ) Qᵢₙ   when Hₛ + ΔH > Hᴅ + Hᶜʰᵉᶜᵏ
Pᵢₙ = ρgHₛQᵢₙ   ·   Pₒᵤₜ = ρgHᴅQₒᵤₜ

Model scope. This is a reduced-order teaching model, not a transient CFD solver or a pump-sizing tool. It uses a fixed Darcy friction factor (0.025), lumped minor-loss coefficient (K = 2), wave speed (900 m/s), check-valve allowance (0.5 m) and nominal energy efficiency (55%). The air chamber damps delivery-flow ripple with an illustrative exponential relation; it does not alter the idealised valve-side Joukowsky peak. Values are illustrative and should not be used for construction or safety decisions.

Readouts are calculated from the stated equations. The independent check evaluates the pressure/head relation in two forms and closes the hydraulic power balance separately.

Made with 🤖 ChatGPT