Fluid power · Hydrology

Hydraulic ram pump laboratory

2D · Flow & data
Hydraulic cycle · sectional view
Supply flow → waste-valve closure → pressure surge → delivery pulse
Delivery active
Drive flow
—L/min
Source through drive pipe
Delivered flow
—L/min
Useful lifted water
Water-hammer peak
—m
Head above pump datum
Hydraulic efficiency
—%
Useful output / input power
Cycle frequency
—Hz
Approximate reset cycle
Waste flow
—L/min
Non-delivered supply flow

Operating envelope

Predicted delivery vs. delivery head
The science · model, assumptions & independent check
v = √[2 g Hs / (1 + K + f L/D)]   ·   Qs = (πD²/4) v
ΔH = a c v / g   ·   Hpeak = Hs + ΔH
Qd = ηmax · Fvalve · Qs · Hs/Hd   ·   η = ρgQdHd / (ρgQsHs)

Textbook basis: Darcy–Weisbach pipe losses, Swamee–Jain turbulent friction factor, and the Joukowsky water-hammer relation. Illustrative closure model: the effective closure fraction represents the portion of drive velocity removed over a rapid pressure-wave interval. A smooth valve threshold activates delivery when peak head exceeds delivery head plus a cracking allowance.

Scaled / simplified: the real ram is a transient fluid–structure system. This compact model does not solve the full method-of-characteristics wave field, valve inertia, air-chamber gas compression, cavitation, pipe elasticity, or cycle-resolved waste-valve motion. The estimated cycle frequency is a recovery-time approximation; the steady energy ratio is enforced by the delivery-flow closure.

Independent power-ratio check—

Mass balance: drive flow = delivered flow + residual waste flow. The pressure surge is a head estimate, not a pipe pressure-rating recommendation.

Illustrative design, not affiliated with any real institution or manufacturer. SI model · educational engineering approximation · no real pump sizing certification.

Made with 🤖 ChatGPT