Drag to orbit • Scroll to zoom
Lava in a tube is insulated by its roof, so it loses heat slowly. For a full conduit of radius R carrying volume flux Q the energy balance rho c_p Q dT/dx = -U (2 pi R)(T - T_env) gives T(x) = T_env + (T_0 - T_env) exp(-x/L_c) with L_c = rho c_p Q / (2 pi R U); real insulated tubes cool only about 1-10 C per km (Keszthelyi 1995).
Viscosity follows a Vogel-Fulcher-Tammann law, log10 mu = -3 + 4500/(T - 450) (T in C), an illustrative fit for basalt (about 10^3 Pa s at 1150 C, 10^5 Pa s near 1000 C). Laminar gravity-driven flow in a pipe obeys Hagen-Poiseuille: v_mean = rho g sin(theta) R^2 / (8 mu) and Q_cap = pi R^4 rho g sin(theta) / (8 mu). If the supply Q exceeds Q_cap at the cold end the lava backs up (pressurises the tube or overflows); otherwise the tube is partly filled by the fraction f = Q/Q_cap.
Reynolds number Re = rho v 2R / mu stays far below 2000, so the flow is laminar. The independent checks (1) solve the radial momentum equation mu (1/r) d/dr (r du/dr) = -rho g sin(theta) by finite differences and compare the mean speed with the closed form, and (2) integrate dT/dx with Runge-Kutta 4 and compare with the exponential solution.
Simplifications: Newtonian lava (no yield strength, crystals or bubbles), constant density and heat capacity, full-conduit heat loss, no latent heat or tube erosion, a constant slope. The 140 m tube in the 3D scene is a schematic reach, not to the scale of the L slider; its colour runs from the vent temperature to the end temperature and its flow speed follows the computed velocity.