✧MYSIMULATORATLAS OF ATLANTIS / EXPERIMENT 017
INTERACTIVE ENGINEERING EXHIBITORIGINAL SIMULATION · 2026
THE LOST ENGINEERING ARCHIVES / VOL. IX

KHEMORA ✳THE SEISMIC CROWN

Command an impossible Atlantean sanctuary built on moving foundations. Send tremors through ancient bedrock, retune its isolation bearings, and discover whether engineering or resonance decides the city's fate.

✦ REAL-TIME STRUCTURAL DYNAMICS✦ INTERACTIVE WEBGL2 MODEL✦ 4 QUAKE PROFILES
DYNAMICS LIVE
SCENE 01 / THE CROWN
N✧S
DRAG ORBIT· SHIFT + DRAG PAN· SCROLL ZOOM· CLICK INSPECT
BUILDING THE CITADELForging procedural architecture and foundation instruments…
◎
OBJECT INSPECTOR · CLICK THE MODEL TO EXPLORE

The isolated citadel

A four-degree-of-freedom stone structure rides above six fictional bronze-viscous seismic bearings. Select a tower, deck, spring or fault to inspect its live role.

BEDROCK ACCELERATION
0.00 m/s²
Ground quiet
ROOF SWAY
0 mm
Relative to undisturbed position
PEAK INTERSTOREY DRIFT
0.00 %
Within design tolerance
STRUCTURAL INTEGRITY
100 %
LIVE SEISMOGRAPH DISPLACEMENT · METRES
Ground Roof
FIELD NOTE 017 / PRINCIPLE

When the earth moves,
the tower need not follow.

A flexible seismic-isolation layer can shift an elevated structure's dominant period away from damaging ground motion. But isolation creates travel, and resonance can still defeat a poorly tuned system. In Khemora, each lever exposes that trade-off rather than hiding it.

THE CODEX / EXPERIMENTAL ARCHIVES

Inside the Seismic Crown

Engineering, archaeology and fiction meet in one virtual experiment. Read the notes below to understand the simulated mechanism—and the boundaries of the story.

I / OVERVIEW

A citadel made to move

Khemora imagines a ceremonial archive standing on a fault-struck Atlantean headland. It is not a destroyed temple, a submerged city or a passive architectural tour. Its central question is dynamic: how can a tall stone building remain comparatively stable when its foundation is being shaken? The player operates a seismic laboratory by selecting an earthquake profile, adjusting the properties of the supporting structure and watching its response in real time. These elements are linked by a numerical representation of masses, springs and dampers.

The display separates bedrock movement, crown displacement, storey drift and cumulative integrity. A structure can have modest absolute motion and still experience dangerous relative deformation between storeys; likewise, an isolation platform can protect the tower while moving a considerable distance relative to its footings. The instrument panel encourages comparisons between those outcomes rather than presenting a simplistic pass-or-fail verdict.

II / A FICTIONAL ATLANTIS

The Wardens of the Deep Fault

In the imagined late Golden Age of Atlantis, the Wardens of the Deep Fault discovered that tightly built monuments could fracture under repeated coastal tremors. Their response was the Crown: a monumental civic library whose bronze-mounted base was designed to slide and yield rather than resist every movement. An ornate moving counterweight near the summit helped settle prolonged oscillations.

These Wardens, structures, devices and dates are original mythology created for this exhibit. There is no archaeological evidence for Atlantean seismic engineering, and no verified historical location of Atlantis. Plato's dialogues Timaeus and Critias are the earliest surviving literary sources for the famous island story. This simulation uses that cultural inspiration without treating the legendary civilisation as established history.

III / MATERIALS & SCENE

Bronze, stone and open air

The procedural scene is composed of layered octagonal platforms, columns, roof fins, stylised bronze bearings, piston-like dampers, tapered spires, masonry terraces and an exposed geological fault. Six large bearing stations support the raised plinth; their visible coils and rods communicate the idea of elastic and dissipative connections. The principal tower is constructed as distinct moving levels. When an earthquake arrives, adjacent floors do not simply move as one rigid sculpture: their positions respond to a coupled structural model. The crown's little bronze mass travels on a rail of its own, revealing the counter-motion of a tuned absorber.

Surface highlights, fog, procedural geometric detail and animated wavefronts provide depth without requiring photographs, downloaded textures or expensive rendering assets.

IV / PHYSICS ENGINE

A simplified system of motion

At its core, the engine advances coupled second-order differential equations using fixed-duration numerical integration steps. The isolated foundation and three structural levels are represented as four horizontal masses. Each adjacent pair is joined by an effective spring and dashpot. The base connects to moving ground through a spring-damper bearing system, and a fifth degree of freedom represents the crown's tuned mass damper when its mass ratio is greater than zero. Force follows the idealised linear relation F = −kΔx − cΔv: elastic resistance rises with relative displacement, while damping opposes relative velocity.

Different presets introduce a compact pulse, slowly varying motion, two separated shocks or sustained forcing. Actual earthquakes have far richer broadband frequency content, soil interaction, rotations, nonlinear failure and uncertain acceleration histories. The displayed acceleration is derived from the imposed ground movement; storey drift is the largest relative floor displacement divided by an assumed storey height.

V / OPERATION

Conducting a test

Start with Single Rupture and press Trigger Quake. Watch the rocky ground ring respond, then follow the moving foundation and roof. The gold seismograph line represents ground displacement, and the blue line depicts roof displacement in the same world coordinate system. Use Pause to freeze the numerical process while studying an instant; Resume continues from that state. Reset restores displacement, velocity, damage, timeline and graph history without discarding the values currently selected on your controls. The camera can be orbited by dragging, panned by Shift-dragging or right-dragging, zoomed with the wheel, and reset from the view toolbar.

Click the ground fault, a spring bearing, a terrace, a tower level or the counterweight to inspect its purpose and current state. Camera presets reveal the whole scene, the foundations, the structural elevation and the crown's plan. On a touchscreen, one-finger dragging orbits, while two-finger motion supports panning and pinch zoom.

VI / TUNING EXPERIMENTS

Design choices with consequences

There are ten continuous controls: quake strength, wave frequency, wave-train duration, bearing stiffness, bearing damping, tower rigidity, architectural mass, counterweight ratio, counterweight tuning and simulation speed. The first three reshape the external input. The next four alter how the structure transfers forces. The counterweight settings change the absorber's influence on crown motion; speed changes only how quickly simulated time passes. Emergency Bearing Lock replaces the compliant base with a much stiffer restraint, allowing direct A/B comparisons between isolated and anchored behaviour. Equilibrium Guides reveal where each tower level would sit without any horizontal excitation.

For a good experiment, trigger a quake, record peak drift and roof motion, reset, change one control and repeat with the same event. A softer foundation may greatly reduce upper-storey drift while increasing bearing travel. More damping may limit oscillation after a shock, but extremely stiff or highly damped isolation can transfer more ground motion to the protected structure. Stronger towers move differently from heavier towers because stiffness and inertia jointly determine natural frequencies.

VII / REAL SCIENCE

Resonance and isolation

Seismic isolation is a real engineering method used to reduce the horizontal forces transmitted from moving ground to buildings and other important structures. Isolation bearings are often designed to provide lateral flexibility together with restoring force and energy dissipation. Real examples use technologies such as elastomeric bearings, lead-rubber bearings, sliding pendulum devices and dedicated damping systems. Its ornamental coil and piston arrangements represent equivalent mechanical behaviour rather than an engineering blueprint.

Resonance matters because repeated forcing near a structure's characteristic frequency can amplify its response. A tuned mass damper works by allowing an auxiliary mass to move out of phase with the main structure, redistributing and dissipating some vibrational energy near its designed operating range. These ideas appear in modern civil engineering, precision instruments and machinery. The exhibit lets visitors see why a well-matched design can outperform the superficially strongest or heaviest arrangement.

VIII / ADVANCED EXPLORATION

From observation to hypothesis

Try a parametric sweep: keep the earthquake profile constant, change foundation stiffness across several runs and compare the blue roof trace with the gold ground trace. Next, increase damping while holding stiffness fixed. Then set the auxiliary mass to zero; restore it gradually and alter its tuning ratio to discover which setting reduces the most visible sway for your chosen excitation. For a deliberately difficult trial, use Resonance Trial, adjust wave frequency until tower motion grows and compare isolated and locked foundations.

The visual integrity score decreases when modelled storey drift exceeds a chosen illustrative threshold. This is a teaching device, not a calibrated failure model. You may see substantial harmless-looking foundation travel while the superstructure remains mostly aligned, or modest-looking movement coupled with higher storey deformation. That distinction is central to earthquake engineering.

IX / HIDDEN DETAILS

The language of the Crown

The six bearing stations are arranged around the base to make the mechanical separation easy to identify from different camera angles. The apparent fault radiates bright, transient rings when a shock is active. Fine reference guides indicate equilibrium, and the crown's moving mass changes its position independently of the main roof. Surrounding towers and terraced retaining stones do not perform structural calculations: they place the experimental subject within an imagined coastal settlement. The instrument panel uses real dimensional labels for displacement and acceleration, alongside dimensionless stiffness multipliers and a percentage integrity indicator.

The random generation seed identifies the arrangement of procedural ornamental details and the exact product edition. The visual architecture is created from programmatic geometry, so the experience ships without third-party models, fonts or textures.

X / LIMITS & HONESTY

Where the model stops

Khemora is a fictional educational toy, not a building-code analysis package, not a ground-motion forecast, and not a structural safety evaluator. It assumes horizontal motion along one principal axis and small, linearly elastic deformations. It omits torsion, three-dimensional coupled seismic components, soil-structure interaction, nonlinear bearings, cumulative fatigue mechanisms, material fracture, falling objects, occupancy and site-specific hazard. Graph data are short-lived in-memory samples, not exported scientific measurements. The damage indicator follows an intentionally simplified drift-based rule; its percentage must not be interpreted as a real likelihood of collapse.

The numerical system is constructed for intelligibility and stable browser execution rather than strict dimensional resemblance to a real stone citadel. Even the most pleasing configuration should be treated as an experiment in concepts. In the real world, earthquake-resistant design requires qualified engineers, validated simulations, site investigations and compliance with applicable standards. Within those clear limits, the model offers a memorable way to explore inertia, stiffness, damping, period shifting and active experimentation.

TEN QUESTIONS / THE ARCHIVE ANSWERS

Questions from the fault line

Expand any question to explore the mechanics and mythology behind Khemora.

01 What exactly is being simulated in the Seismic Crown?+

The experiment simulates the horizontal response of an invented tall Atlantean archive when its supporting ground moves during an earthquake. It uses four main masses—one foundation deck and three tower levels—connected by ideal springs and dampers. A separate moving mass near the roof can act as a tuned vibration absorber. These five coupled coordinates are advanced through time so the structure bends and sways in response to user-controlled shaking. The scene also animates stylised isolation bearings, a fault and earthquake wavefronts. The numbers are educational approximations, not predictions for a real building. The important outcome is the relationship among input motion, foundation travel, roof displacement and relative deformation between levels.

02 Why can a flexible foundation outperform a rigid one?+

A rigid connection makes a building follow rapid ground motion more directly, potentially transmitting large accelerations and internal forces. A laterally flexible isolation layer changes the dynamics by increasing the effective period of the supported structure. For suitable earthquake frequency content, this can reduce the deformation that develops in the building above. The trade-off is that the isolated base may travel farther relative to the moving ground, so a real project must provide sufficient clearance and control its bearings. In this experiment, lower bearing stiffness allows more foundation motion, and Emergency Bearing Lock offers a dramatically stiffer comparison. Neither option is universally superior; the result depends on the chosen ground wave, building mass and damping.

03 How do I make a fair comparison between two designs?+

Begin by choosing a named earthquake profile, then set the strength, frequency and duration to values you can remember. Trigger one event and inspect the peak interstorey drift, roof sway and integrity indicators. Use Reset to clear accumulated motion and damage. Modify just one variable—such as bearing damping—before triggering the same event again. Keep the camera viewpoint similar when visually judging the results, since perspective can exaggerate or conceal motion. For a richer experiment, try several forcing frequencies and not just one convenient setting. The controls remain at their chosen values after Reset, making repeated trials practical. This is a simple form of controlled experimentation rather than a formal engineering design study.

04 What do the four earthquake scenarios actually change?+

Single Rupture generates a compact transient envelope with a fairly sharp onset and decay. Long-Period Swell favours slow, smooth ground displacement, which can be particularly revealing for a flexible structure. Twin Fault adds a second delayed surge, inviting the building to respond before it has fully settled from the first. Resonance Trial delivers a more sustained, rhythmic wave train, making repeated forcing easier to explore. The strength, frequency and duration controls continue to modify the selected profile. These are synthetic teaching signals, not recordings from named historical earthquakes. They deliberately isolate behaviours that would usually be superimposed in complicated real ground-motion histories. Switching a profile changes the input pattern used by the next and any currently active event.

05 How does the moving crown counterweight reduce vibration?+

The crown contains a simplified tuned mass damper: a smaller auxiliary weight attached to the roof by its own spring and dashpot. When the roof starts moving, the auxiliary mass can move with a different phase and exchange energy with the tower. Near the system's tuned frequency, this interaction can reduce the response of the main structure. Increase Tuner Mass Ratio to give the absorber more inertia, and vary Tuning Ratio to alter its natural frequency relative to the tower. Setting mass ratio to zero effectively removes its dynamic contribution. The Apply Counterweight Impulse button introduces a brief velocity change, making the coupling visible even without an earthquake. Real tuned dampers have carefully engineered constraints, damping and travel limits absent here.

06 What does the structural integrity percentage mean?+

The integrity indicator is a deliberately artificial teaching score driven by excessive calculated interstorey drift. If adjacent tower floors move too far apart relative to the assumed storey height, the program gradually reduces the percentage. This creates a persistent consequence for badly configured experiments and encourages comparisons beyond spectacular visual shaking. It does not incorporate stress distribution, masonry cracking, collapse mechanisms, material properties, multiple loading directions or the code-defined performance limits used by engineers. In particular, an indicated score of 100% is not evidence of safety, and a lower score does not establish actual damage or failure. Reset clears the indicator so that experiments can be repeated. Treat it as a gameplay-like warning metric, not an engineering certificate.

07 Can I navigate the model and inspect individual mechanisms?+

Yes. Drag on the scene to orbit; use the mouse wheel to change distance. Hold Shift while dragging, or use the right mouse button, to pan the camera target. Touch devices support one-finger orbit and two-finger pan and pinch zoom. The toolbar provides an overview, a close foundation view, an elevation, a plan view and a camera reset. Clicking a major component opens a contextual explanation in the inspector directly below the viewport. The Focus button moves the camera to that component. Selecting the moving foundation, spring bearings, upper storeys, crown counterweight or geological fault helps connect visible movement to the underlying physics. Inspection and camera navigation remain available while numerical time is paused.

08 Was there really an Atlantean technology for earthquake protection?+

No verified archaeological evidence supports the existence of Atlantis as a historical engineering civilisation, let alone a specific seismic-isolation device or a citadel called Khemora. Atlantis is principally known from Plato's ancient Greek dialogues, and later artists have repeatedly reimagined it. This project is an original fictional interpretation of that tradition. Seismic isolation itself, however, is real and has been developed through modern engineering research, testing and construction. The interface therefore distinguishes two layers: an invented mythological setting and a simplified demonstration of real physical principles. The bronze mechanisms are visual metaphors for equivalent spring and damping behaviour, not archaeological reconstructions or claims about lost scientific knowledge.

09 Why do mass, stiffness and frequency change the outcome so much?+

Every vibrating structure has characteristic natural frequencies associated with how strongly it resists deformation and how much inertia it possesses. Increasing stiffness tends to increase frequency, while increasing mass tends to decrease it, although a multi-storey system has several coupled modes. When a forcing signal repeatedly pushes near a responsive mode, motion can become amplified. The bearing system changes the overall dynamic character of the tower, while the auxiliary mass introduces another interacting oscillator. Try raising the wave frequency in Resonance Trial and watching the blue roof trace. Then change architectural mass or tower rigidity while leaving the ground signal unchanged. The resulting changes demonstrate why earthquake response cannot be explained by strength or weight alone.

10 What are the model's technical and scientific limitations?+

The engine is a browser-based, fixed-time-step demonstration with idealised linear stiffness and viscous damping. It calculates one horizontal direction rather than complete six-degree-of-freedom structural motion. Ground profiles are synthetic; no recorded accelerograms or geotechnical data are supplied. The structure does not realistically crack, buckle, collide with neighbouring buildings, or permanently deform. The stylised integrity metric is not calibrated to a real construction material or accepted structural performance standard. Fast animations and explanatory effects may be exaggerated visually so visitors can recognise small differences. These compromises make the exhibit interactive and understandable on ordinary devices, but they prevent it from serving as a professional seismic assessment. Use the simulation to ask better engineering questions, not to certify actual earthquake resistance.

Made with 🤖 ChatGPT · Three.js