Cause → mechanism → result
A lightning channel deposits energy into a narrow path through quartz-rich sand. The hot core heats adjacent grains; silica crosses its melting interval, wets and fuses grains into a glassy wall. The channel interior can remain hollow as gas escapes and the melt quenches.
∂H/∂t = (1/r) ∂/∂r [ r k ∂T/∂r ] + q̇(r,t)
α = k / (ρ cₚ) · ℓᵈ ≈ √(4 α t)
- H
- Specific enthalpy, J kg⁻¹, including phase-change plateaus
- k
- Effective thermal conductivity, W m⁻¹ K⁻¹
- ρ
- Bulk quartz-rich sand density, kg m⁻³
- cₚ
- Effective heat capacity, J kg⁻¹ K⁻¹
- q̇
- Radially distributed, time-limited absorbed discharge energy
Assumptions & limits: Axisymmetric radial conduction around the main channel; branching paths are prescribed visual geometry, not thermally coupled. Effective homogeneous sand; simplified water evaporation and silica fusion enthalpy. Fully vaporised cells are capped, with excess energy assigned to the escaping plume. No plasma chemistry, electromagnetic breakdown, multiphase gas flow, grain-scale fracture or full 3D thermo-mechanics. Tube geometry is enlarged ×8 for visibility.
Independent validation: a separate linear Gaussian line-source diffusion test is compared with its analytical heat-kernel solution. This checks the radial conduction solver, not the complete fulgurite process.
Illustrative educational model, not affiliated with any real institution or manufacturer.