INTERACTIVE SCIENCE / EARTH
LOCAL PHYSICS ENGINE3D · WEBGL
✦ RARE EARTH PHENOMENA / EXHIBIT 004

When Lightning Makes Glass.

Explore the hidden architecture of a fulgurite—a branching, glass-lined fossil of an electrical discharge buried in sand.

PHENOMENONFulgurite formationGeology · Silica vitrification
DISCHARGE / THERMAL EVOLUTION0.00 s
STARTPULSE · 0.52 sCOOLING · 16 s
01 / CAUSECurrent enters sand
→
02 / MECHANISMJoule heat & melting
→
03 / RESULTGlass-lined channels
ΣThe ScienceGoverning equations · physical constants · validation · limitationsEXPLORE ⌄

01 / Electrical heating

The lightning channel deposits an illustrative fraction of its electrical energy per unit length into a radial column of sand:

E′ = η I² [ρₑ / (π a²)] τ

Here I is peak current (A), ρₑ effective hot-channel resistivity (Ω·m), a channel radius (m), τ pulse duration (s), and η a user-set coupling factor. Energy is distributed as a normalized Gaussian about the channel. The time profile is normalized sin².

02 / Heat transport & phase change

Finite-volume, axisymmetric enthalpy diffusion uses cylindrical shell areas and exact source integration:

ρ ∂h/∂t = (1/r) ∂/∂r [ r k ∂T/∂r ] + Q‴

Fixed 1 ms timestep; 140 annular control volumes; outer boundary held at 293.15 K. Piecewise enthalpy accounts for 373.15 K moisture boiling, fusion at 1,986 K and simplified silica vapour escape. Peak historical melt fraction determines the retained glass cross section.

03 / Independent validation

With latent heat and source terms disabled, a separate Gaussian thermal test starts from ΔT(r,0)=A exp(−r²/w²). The infinite-medium heat kernel predicts:

ΔT(0,t) = A w² / (w² + 4αt)

A = 72 K; w = 6.5 mm; t = 18 s; α = k/(ρc). The displayed engine and reference values are computed when the page loads, not prefilled. The cold boundary is far enough away to have negligible influence during this test.

Model scope and sources

TEXTBOOK values: silica fusion point 1,986 K; water vapour latent heat approximately 2.26 MJ/kg. ILLUSTRATIVE values: bulk-sand heat capacity 820 J/(kg·K), density 1,600 kg/m³, fusion latent heat 150 kJ/kg and selected channel-coupling parameters. SCALED: tube width is visually enlarged 3.5×, and electric branches are stylised; branching has no coupled network-electric solver.

The thermal model is a single radial cross section repeated along idealised branches. It does not solve leader attachment, transient electromagnetic fields, hydrodynamic blast excavation, multi-mineral chemistry, non-equilibrium plasma, spatial moisture transport, or crack mechanics. Do not use it to predict lightning risk or field fulgurite yield.

Scientific context: Experimental generation of fulgurite under realistic lightning discharge conditions (Scientific Reports, 2023); Pasek et al., Fulgurite Morphology (2012); Particle Data Group, silicon dioxide physical properties (2020).

Made with 🤖 ChatGPT · Three.js