Why Small Pipe Leaks Grow
Under Higher Pressure
A tiny opening can waste more water than its size suggests. Explore the balance between pump head, pipe friction, leak pressure and the flow that still reaches a tap.
The pump supplies a fixed head. Flow divides at the leak, then the remaining water travels through the downstream pipe to the tap.
Independent numerical checks
Does leak flow follow the pressure law?
Increase pump head by an illustrative 10%, solve the network again, then compare the measured leak-flow ratio with the pressure-response equation.
REFERENCEThe science+
Flow through the leak and tap
The leak is represented by a pressure-driven discharge law:
At the reference head, Qref = CdAref√(2gHref). With n = 0.5 (textbook fixed-orifice reference), this is the ordinary fixed-orifice equation. Larger n represents an effective opening that expands as pressure rises; it is a useful phenomenological model for some flexible cracks, not a universal material law.
The tap is treated as a fixed orifice: QT = CdAT√(2gHT).
Pipe friction and the network balance
The Darcy friction factor is calculated with the textbook laminar relation 64/Re and the Haaland explicit approximation for turbulent flow, with a smooth blend through the transition region. The two unknown pressures are found by nested bisection:
Continuity at the junction is Qin = QL + QT. The calculation uses g = 9.81 m/s², water density 998.2 kg/m³ and kinematic viscosity 1.004 × 10⁻⁶ m²/s as textbook reference values near 20°C.
What is simplified
- The network is one straight, level main with one leak and one outlet. Elevation changes, fittings, branches and changing pump curves are omitted.
- Water is incompressible and the result is steady-state. Water hammer, pump start-up, pipe-wall motion and cavitation are not simulated.
- The discharge coefficient is fixed at 0.62. Pipe sizes, pump head, hole sizes, roughness, service target and the leak exponent are illustrative controls, not specifications for a real system.
- The leak exponent is a model choice. The textbook value 0.5 describes a rigid orifice; larger values represent stronger pressure sensitivity in an effective crack-opening law.
Interpretation: this is an educational hydraulic model, not a design tool. All scene dimensions and flow animations are scaled for clarity; numerical readouts are calculated from the equations above.