Water rises and falls in the tower as momentum moves through the connecting pipe.
Give the water a push. Watch the tower and pipeline exchange energy.
Water rises and falls in the tower as momentum moves through the connecting pipe.
A reservoir supplies a horizontal pipe of length L and area Aₚ to a vertical surge tower of area Aₜ. The large reservoir holds a fixed reference level. The model tracks tower level offset h and mean pipe velocity v.
Continuity: dh/dt = (Aₚ/Aₜ)v. Momentum: dv/dt = −(g/L)h − (r/L)v, with g = 9.81 m/s². The damping coefficient r has units m/s; it is a linearised illustrative loss term. Numerical evolution uses fourth-order Runge–Kutta at a fixed 0.01 s step.
Ideal period: T₀ = 2π√(LAₜ/(gAₚ)). Energy: E = ½ρLAₚv² + ½ρgAₜh², where ρ = 1000 kg/m³. Its predicted dissipation rate is dE/dt = −ρAₚrv². We independently compare the ideal-period formula with a numerical quadrature of the ideal oscillator, full-step against half-step integration, and energy loss against integrated dissipation.
Illustrative cross-section, constant-density incompressible water, rigid pipe, fixed reservoir level, spatially uniform pipe velocity, no water hammer wave propagation, no cavitation and no nonlinear turbulence. The tower has a finite displayed freeboard; crossing it flags an overflow failure, but spilled volume is not modelled. This is not a pressure-surge safety design tool. No brand affiliation.