MY SIMULATOR / HYDROLOGY LAB

Water Tower Surge The Hidden Pipe Oscillation

Give the water a push. Watch the tower and pipeline exchange energy.

LIVE HYDRAULIC MODELRUNNING
Water Equilibrium

Water rises and falls in the tower as momentum moves through the connecting pipe.

The science Equations, assumptions and limits

A reservoir supplies a horizontal pipe of length L and area Aₚ to a vertical surge tower of area Aₜ. The large reservoir holds a fixed reference level. The model tracks tower level offset h and mean pipe velocity v.

Continuity: dh/dt = (Aₚ/Aₜ)v. Momentum: dv/dt = −(g/L)h − (r/L)v, with g = 9.81 m/s². The damping coefficient r has units m/s; it is a linearised illustrative loss term. Numerical evolution uses fourth-order Runge–Kutta at a fixed 0.01 s step.

Ideal period: T₀ = 2π√(LAₜ/(gAₚ)). Energy: E = ½ρLAₚv² + ½ρgAₜh², where ρ = 1000 kg/m³. Its predicted dissipation rate is dE/dt = −ρAₚrv². We independently compare the ideal-period formula with a numerical quadrature of the ideal oscillator, full-step against half-step integration, and energy loss against integrated dissipation.

Illustrative cross-section, constant-density incompressible water, rigid pipe, fixed reservoir level, spatially uniform pipe velocity, no water hammer wave propagation, no cavitation and no nonlinear turbulence. The tower has a finite displayed freeboard; crossing it flags an overflow failure, but spilled volume is not modelled. This is not a pressure-surge safety design tool. No brand affiliation.

Made with 🤖 ChatGPT