Coupled fluid–structure model
The cylinder is a one-degree-of-freedom oscillator. Its transverse displacement is y; the wake state is q. Time integration uses fixed-step fourth-order Runge–Kutta.
Ÿ + 2ζωₙẎ + ωₙ²Y = ½ CL U² q / (m* D²)
q̈ + εωₛ(q² − 1)q̇ + ωₛ²q = A Ÿ
fₛ = St · U / D ; Uᵣ = U / (fₙD)
Reference values: St = 0.20 is a textbook-style estimate; ρ = 998.2 kg/m³ and ν = 1.004 × 10⁻⁶ m²/s are textbook water properties near 20 °C. The wake coefficients ε = 0.30 and A = 0.02, the lift scale, and the ±0.65D travel stop with restitution 0.25 are illustrative.
What is simplified
- The van der Pol wake oscillator is a reduced-order representation, not a resolved fluid simulation.
- Lift is represented by a single fluctuating coefficient scale. Added mass, spanwise variation, turbulence, end effects and detailed support mechanics are omitted.
- The alternating vortex street is a visual schematic driven by wake phase. It is not a CFD velocity or pressure field.
- Travel stops at ±0.65D use a simple impact restitution of 0.25. Contact stress and structural damage are not calculated.
- Below Re ≈ 47, the periodic wake oscillator is disabled to represent the absence of sustained periodic shedding behind an ideal circular cylinder.
Interpretation: use the model to explore frequency matching, damping, mass ratio and response trends. It is an educational reduced-order model, not a design or safety tool. The water properties and Strouhal estimate are textbook reference values; coupling constants and support limits are illustrative.