Venturi Cavitation: When Water Boils Without Heat
A narrowing passage accelerates water. Watch its pressure fall to the vapour threshold — then recover downstream.
Find the first-bubble speed
Numerically sweep inlet speed until the ideal throat pressure reaches the water-vapour threshold. Compare the measured step with the closed-form prediction.
Numerical checks
All differences are recomputed from the current controls. These are textbook-equation checks, not physical validation.
REFERENCE NOTESThe science+
Governing equations
Continuity: for incompressible water, Q = Av. If the throat diameter is a fraction β of the inlet diameter, its area is β²A₁ and its speed is vₜ = v₁/β².
Bernoulli with a contraction loss: pₜ = p₁ − ½ρ(1 + Kc)(vₜ² − v₁²). The diffuser recovers a selected fraction η of the ideal dynamic-pressure rise: p(x) = pₜ + η·½ρ(vₜ² − v(x)²).
Vapour threshold: cavitation is possible where the single-phase pressure estimate falls below the saturation vapour pressure pᵥ(T). The displayed cavitation number is σ = (p₁ − pᵥ)/(½ρvₜ²).
Water vapour pressure: the Antoine relation is used over the selected temperature range: log₁₀(PmmHg) = A − B/(C + T°C), with water constants A=8.07131, B=1730.63, and C=233.426.
What is simplified
The passage is treated as a one-dimensional, steady, incompressible flow with a prescribed inlet speed. The model applies a simple contraction-loss coefficient and a user-selected diffuser pressure-recovery factor. It screens for the first vapour-pressure crossing; it does not solve a coupled two-phase flow, choking, turbulence, dissolved-gas transport, or erosion.
What is illustrative
The glass apparatus, water streamlines, bubble count, bubble sizes, and animation timing are visual explanations. Bubble size is an illustrative response to local pressure deficit, not a Rayleigh–Plesset bubble-dynamics solution. The tube proportions are scaled, not a manufacturing drawing. All pressure and speed readouts are calculated from the equations above.
When the uncavitated estimate falls below zero absolute pressure, the single-phase model has failed. The real flow would redistribute, choke, or change its flow rate; the negative value is never shown as a physical pressure.
Reference basis: standard incompressible Bernoulli and continuity relations; Antoine saturation-pressure correlation for water. This educational model is not affiliated with any equipment manufacturer.