Why the pressure falls
For steady incompressible flow, continuity gives Q = A v. The narrowing tube reduces area, so the water speeds up. Along a streamline, the ideal Bernoulli relation is p + ½ρv² = constant. Static pressure therefore falls as kinetic energy per unit volume rises. The displayed cavitation number is σ = (pᵢₙ − pᵥ) / [½ρ(vₜ² − vᵢₙ²)]. In this idealised geometry, σ < 1 indicates that the throat pressure estimate has crossed the vapour-pressure threshold.
How the bubble responds
The representative nucleus follows a Rayleigh–Plesset form: R R̈ + ³⁄₂ Ṙ² = [pᵥ + pᵍ(R) − p∞ − 2γ/R − 4μṘ/R] / ρ. The gas term is approximated as pᵍ(R) = pᵍ₀(R₀/R)^(3κ). An illustrative fixed one-microsecond RK4 step advances radius and radial velocity along a prescribed pressure path. The rendered bubble is enlarged and is not a literal size measurement.
What is simplified
The tube is axisymmetric and the flow is treated as steady, incompressible and one-dimensional at each cross-section. A small illustrative diffuser loss is applied. The pressure profile is a single-phase Bernoulli estimate; it does not solve a two-phase mixture, turbulence, boundary layers, heat transfer, bubble-bubble interaction or erosion. The gas nucleus is one representative tracer, not a population model. Within the predicted cavitation zone, the tracer pressure is clamped at vapour pressure to approximate pressure pinning; this is not a full cavitating-mixture closure. Once the predicted pressure falls well below vapour pressure, the single-phase estimate is outside its reliable range — the “Flow breakdown” preset deliberately demonstrates that limit.
Numbers and references
Water density, viscosity and surface tension use temperature-dependent textbook approximations; vapour pressure uses the Antoine saturation-pressure relation. The Rayleigh collapse coefficient 0.915 is a textbook result for an empty spherical cavity in an infinite liquid under constant pressure difference. Adjustable operating conditions and the diffuser-loss allowance are illustrative. The apparatus drawing and bubble scale are scaled for visibility. This exhibit is educational and does not predict the performance or safety of a real pump, valve or pipe.