ENERGY & INFRASTRUCTURE · EXPERIMENTAL MODEL

The Rise and Fall of
Water in a Surge Tank

Release a displaced water column. Watch inertia carry it past equilibrium—and see how resistance turns that movement into heat.

SURGE TANK APPARATUS
DRAG TO PAN · ILLUSTRATIVE CUTAWAYRUNNING
WHAT YOU'RE SEEING

The main is filling the low surge tank. Flow inertia will carry water past the reservoir's level.

MODEL TIME · SCALED PLAYBACK0.0 s
LEVEL RELATIVE TO RESERVOIR−1.80 mILLUSTRATIVE MODEL
WATER-MAIN FLOW0.000 m³/sILLUSTRATIVE MODEL
PIPE VELOCITY0.00 m/sILLUSTRATIVE MODEL
MECHANICAL ENERGY0.00 kJILLUSTRATIVE MODEL
THREE INDEPENDENT CHECKS

Does the model add up?

LIVE COMPARISONS
01 / VOLUME BALANCE✓
0.000%

Independent trapezoidal flow integral vs tank volume change.

ILLUSTRATIVE NUMERICAL CHECK · % DIFFERENCE
02 / ENERGY LEDGER✓
0.000%

Potential + kinetic + integrated frictional heat vs initial energy.

ILLUSTRATIVE CONSERVATION CHECK · % DIFFERENCE
03 / IDEAL CLOCK✓
0.000%

Independent Verlet period measurement vs closed-form small-oscillation period.

TEXTBOOK REFERENCE CHECK · % DIFFERENCE
Textbook frictionless period: 0.0 s · this clock is an ideal reference, not a claim that a lossy cycle takes exactly this long.
ONE MEASURABLE EXPERIMENT

How high will the first crest climb?

Run a separate numerical release until the first turning point. Compare the measured rise above equilibrium with the textbook lossless upper bound.

Not measured yet. This experiment does not alter the live apparatus.
OPEN THE MODELThe scienceEquations, assumptions and limits

We model a large fixed-head reservoir feeding an open, uniform surge tank through one rigid, water-filled pipe. The water is incompressible. Its pipe velocity is represented by one bulk value; the tank surface remains horizontal.

MASS CONTINUITYdh/dt = Q / Aₜ
PIPE MOMENTUMdQ/dt = (g Aₚ / L) [Hᵣ − h − K Q|Q| / (2g Aₚ²)]
IDEAL CLOCKT₀ = 2π √(L Aₜ / (g Aₚ))
ENERGY ACCOUNTINGE = ½ρ(L/Aₚ)Q² + ½ρg Aₜ(h − Hᵣ)²
FRICTIONAL HEATINGdEₗₒₛₜ/dt = ρK |Q|³ / (2Aₚ²)

Textbook constants: gravitational acceleration 9.81 m/s² and liquid-water density 1000 kg/m³. Illustrative inputs: geometry, level offset and the lumped dimensionless loss coefficient. Scaled presentation: live playback advances eight model seconds per wall-clock second; the diagram is not to scale.

The coupled equations are advanced with fixed-step, fourth-order Runge–Kutta integration. The mass check independently sums trapezoidal flows. The energy check integrates irreversible quadratic drag as a separate state. The ideal clock check uses a separate velocity-Verlet calculation. A tank overflow is a stop event: water is not simulated after it reaches the rim.

Limits: no water hammer, pipe elasticity, cavitation, entrained air, downstream demand changes, turbulence resolution, unsteady wall friction or overflow hydraulics. High-speed cases can leave the regime where a rigid, incompressible lumped model is appropriate. The apparatus appearance is illustrative, not an engineering drawing. No company equipment or branding is depicted; not affiliated with any equipment manufacturer.