Water-column inertia
The penstock's moving water cannot stop instantly. Its inertia drives water into the vertical shaft when turbine discharge falls.
dQ/dt = (g Aₚ / L) × (Hᵣ − H − hᶠ)
Aₛ × dH/dt = Q − Qₜ − Qₛ
hᶠ = f × (L / Dₚ) × Q|Q| / (2g Aₚ²)
T₀ = 2π × √(L Aₛ / (g Aₚ))
The last expression is the undamped, small-signal natural period after a rapid turbine closure.
What is simplified
- Water is incompressible and the penstock is represented by one rigid moving column.
- Friction is quasi-steady Darcy–Weisbach loss; turbine discharge follows a prescribed gate law and square-root head relation.
- Overflow uses a simple broad-crested weir relation. Elastic pressure waves, pipe-wall motion, detailed turbine dynamics, air entrainment and three-dimensional flow are omitted.
How to read the numbers
Textbook marks physical constants or established equations. Illustrative marks the selected station and simulated outputs. Scaled marks drawing dimensions only. Gravity is g = 9.81 m/s² (textbook); the numerical step is 0.02 s (illustrative).
This is an educational rigid-column model, not a design, safety or surge-protection assessment for a real hydroelectric installation.