How a salt cavern is dissolved
Fresh water is pumped through a well into a rock-salt bed; the wall dissolves and the brine is pumped back out. At every wall element the salt flux is j = k (cs − c) (kg per m² per s), where c is the local brine concentration, cs the saturated value (about 317 kg/m³, 26 wt % NaCl at 20 °C, rising slightly with temperature) and k a mass-transfer coefficient that grows with temperature. The wall therefore recedes at dr/dt = j / ρs with rock-salt density ρs = 2160 kg/m³. The cavern is cut into 40 stacked layers, each a well-mixed tank of brine: d(mi)/dt = Q (cin − ci) + ji Ai, with the flow passing through the layers in series. In direct circulation fresh water enters at the bottom and brine leaves at the roof, so dense brine sits low and the lower walls see the freshest water; in reverse circulation water enters at the roof, so the top dissolves fastest and the cavern grows upward. A blanket (oil or gas pad) floats on the brine and shields the top of the wall from the water, which is modelled as a protected fraction of the height.
What the page checks
(1) A single well-mixed layer with fixed walls has the exact solution c(t) = c∞(1 − e−t/τ), τ = V/(Q + kA); the numerical integrator is compared with it. (2) With a very large flow the brine stays almost fresh, so the wall must recede at k cs / ρs; (3) at every moment the salt lost by the walls (rock volume removed × ρs) must equal the salt shipped in the brine plus the salt still held in the cavern brine (live balance).
Honest simplifications: an axisymmetric cavern of well-mixed layers (real caverns are irregular, with plumes and layered brine that the layer model only mimics through a density-driven mixing step); k is one effective coefficient (real values depend on natural convection, wall slope and brine density); insoluble layers (anhydrite, clay) that would fall as rubble and form a sump are ignored, as are rock creep, cavern pressure, subsidence and sonar-surveyed shape control; the pipes and the plant are drawn about 5 times oversized so they are visible at 500 m scale; the roof-span warning is an illustrative number, not a stability analysis. Salt density, solubility and the temperature law are typical textbook values. This is an educational model, not a design tool.
What to try
- Press Direct circulation and watch the lower part of the cavern widen first; then Reverse circulation and compare where the wall moves.
- Choose Roof unprotected: the roof radius readout climbs and the span warning appears - that is the roof-fall problem the blanket is there to prevent.
- Try Fast flush: three times the flow grows the cavern faster but the brine leaves under-saturated; read the third graph for the volume and the second for the brine.
- Use the cameras: Roof detail shows the blanket band, Surface plant the pump and tanks whose level rises as brine is produced.