Governing relationships
For a small pressure disturbance in a straight, uniform pipe, the one-dimensional acoustic equations are:
∂p/∂t + (ρa²/A) ∂Q/∂x = 0
∂Q/∂t + (A/ρ) ∂p/∂x = 0
Here p is pressure perturbation, Q is volume-flow perturbation, ρ = 998 kg/m³ is the textbook density of water near room temperature, a is effective wave speed and A = πD²/4 is pipe area.
The pressure-to-flow impedance is Z = ρa/A; its reciprocal Y = A/(ρa) is acoustic admittance. At the tee, pressure is continuous and volume flow is conserved. For a pulse incident in branch k:
pⱼ = 2Yₖ pᵢ / (Y₀ + Y₁ + Y₂)
pᵣ = pⱼ − pᵢ
The transmitted pressure pulse is pⱼ in each outgoing branch. The branch flow pulses are Qⱼ = Yⱼpⱼ. The ideal symmetric tee therefore gives a reflected pressure coefficient of −1/3 and a transmitted coefficient of 2/3 in each branch.
What is simplified
Each pipe is treated as a one-dimensional, uniform acoustic line. The pulse is Gaussian and travels at constant effective wave speed. Junction scattering is solved from the linear pressure-continuity and flow-continuity conditions. A fixed physical time step is used; pulse translation between steps is analytic rather than a frame-rate-dependent animation.
What is illustrative
Pipe bores, lengths, wave speed, pulse amplitude and pulse width are adjustable illustrative inputs. The 350 kPa pressure-rating marker is an illustrative comparison limit, not a universal pipe rating. The rendered pipe geometry is scaled for clarity; it is not a dimensional drawing.
Model limits
The model omits friction, turbulence, fluid-structure coupling beyond the chosen effective wave speed, frequency-dependent attenuation, cavitation, air pockets, fittings with finite geometry and structural failure. The linear acoustic approximation is most useful for small disturbances around a steady operating state. Reflections from the far ends are idealised: the inlet reservoir fixes pressure (pressure reflection −1) and the two outlet valves are closed (pressure reflection +1). The pressure-limit warning does not simulate a burst.
Constants marked textbook: water density 998 kg/m³. All scenario inputs and computed wave values are illustrative. Visual dimensions are scaled.