Partially Filled Tank Sloshing
A small sideways motion can become a large moving wave when the drive matches the tank’s natural rhythm.
The liquid is settling into its first sloshing mode. Watch the surface rise at one wall while it falls at the other.
Measure the steady wave
Run the model through its transient, then compare the measured wall amplitude with the forced-oscillator prediction.
Three numerical checks
THE SCIENCEEQUATIONS, ASSUMPTIONS & LIMITS +
First-mode sloshing
For a rectangular tank of length L and liquid depth h, the first antisymmetric free-surface mode has wavenumber k = π/L. Linear potential-flow theory gives:
The surface is represented by η(x,t) = q(t) sin(kx), with x measured from the tank centre. The modal coordinate q is the wall displacement amplitude.
The tank acceleration is ab(t) = −A(2πf)² sin(2πft). The ordinary differential equation is integrated with fixed-step fourth-order Runge–Kutta at 1/120 s.
What is simplified
- Only the first antisymmetric mode is retained; higher modes and nonlinear wave interactions are omitted.
- The liquid is treated as incompressible, inviscid in the wave derivation, and of uniform density. Damping is represented by one modal ratio ζ.
- The tank is rigid and moves sinusoidally. Structural flexibility, baffles, end-wall details, and three-dimensional effects are not modelled.
- The rim-crossing scenario is a warning from the linear prediction, not a simulation of splash, impact, or actual overflow.
Numbers and scope
Gravity g = 9.81 m/s² is a textbook constant. Tank dimensions, drive settings, damping, and the 0.24 m freeboard are illustrative inputs. Readouts are computed from the stated first-mode model; they are not measurements of a real tank.
The linear model is most useful while the wave height is small compared with the liquid depth and the tank dimensions. When the crest approaches the rim, the assumptions cease to describe the full physical event.