A rotating annulus of seal liquid closes the spaces between the blade tips and casing.
Operating point
LIVE MODELThe science
Each blade pocket follows a sinusoidal volume from clearance Vmin to Vmax. Residual gas expands from discharge pressure until suction opens at Vopen = Vmin (pd/ps)^(1/n). Fresh intake is max(0, Vmax − Vopen) per pocket.
Fresh gas compression follows pVⁿ = constant. The ideal work is ps Vfresh [r^((n−1)/n) − 1] / (n−1), with the logarithmic limit at n = 1. Shaft demand includes a user-set mechanical efficiency and an illustrative seal-liquid shear correlation.
Air is ideal; pressure is absolute; port timing and cell volume are idealised. Liquid dynamics, cavitation, slip, leakage and real pump maps are omitted. The temperature estimate is a polytropic gas estimate, not a casing-temperature prediction. Values are illustrative engineering estimates.
Numerical p–V integral: PASS
Illustrative design, not affiliated with any real institution or manufacturer.
WebGL is unavailable. Showing a schematic fallback.