Junction scattering
For each pipe, the acoustic admittance is Yᵢ = Aᵢ / (ρc), where Aᵢ = πDᵢ²/4. The common junction pressure is
pⱼ = 2 Σ(Yᵢ aᵢ) / ΣYᵢ
The outgoing pressure wave in each arm is bᵢ = pⱼ − aᵢ. This enforces equal node pressure and conservation of volume flow.
Independent conservation checks
Σ Yᵢ(aᵢ − bᵢ) = 0
Σ Yᵢaᵢ² = Σ Yᵢbᵢ²
The second identity is acoustic power conservation for an ideal, lossless junction. The model checks both identities at every integration step.
Wave propagation
Each pipe is represented by a pair of counter-propagating pressure-wave delay lines. A fixed illustrative time step of 0.25 ms advances each sample by one cell. A simple exponential factor applies the selected illustrative amplitude loss per metre.
What is simplified
- Water density is fixed at 998 kg/m³, a textbook reference value for water near 20 °C.
- Wave speed, diameters, lengths, pulse amplitude and attenuation are illustrative inputs, not measurements of a real network.
- The junction is instantaneous, rigid and lossless. The pipes are one-dimensional; bends, wall viscoelasticity, distributed friction, air pockets and cavitation are omitted.
- Branch ends use ideal pressure-release or closed-end reflection coefficients. Real reservoirs, valves and fittings have frequency-dependent behaviour.
- The 1.2 MPa wall-limit marker is an illustrative threshold, not a pipe-rating calculation. The model does not calculate wall stress or predict an actual rupture.