A surge tank is a vertical free-surface chamber connected to a pressurised waterway. When downstream demand changes quickly, the moving water column cannot change speed instantly. The shaft accepts or supplies water while the column slows and reverses.
GOVERNING MODEL TEXTBOOK FORM
Ap = πD²/4 As = πDs²/4
ω₀ = √(gAp / LAs)
ẍ + 2ζω₀ẋ + ω₀²x = 0
x(0) = 0, ẋ(0) = (Ap/As)v₀
x is shaft-level displacement (m), v₀ is the pre-trip pipe speed (m/s), L is effective pipe length (m), and g = 9.80665 m/s² is a textbook gravitational constant.
NUMERICAL INTEGRATION FIXED STEP
Runge–Kutta order four advances the state at a fixed 1/240 s step, independent of display frame rate. The analytic underdamped solution supplies a separate state check.
E = ½(ẋ² + ω₀²x²)
dEloss/dt = 2ζω₀ẋ²
The energy is a normalised mechanical-energy measure per equivalent mass, not a claim about total joules in a real installation.
What is simplified
One effective pipe inertia is coupled to one free surface. Damping is linear and equivalent; the model omits distributed pressure waves, elastic pipe-wall response, nonlinear turbulent friction, air entrainment, cavitation, and the actual turbine or valve dynamics.
What is illustrative
All dimensions, operating speeds, damping values and crest heights are illustrative, not a design recommendation. The drawing is scaled. If the water level overtops the shaft, the model flags the limit but does not calculate spill flow or the altered dynamics.