MySimulator / Field Lab 07

Highland Waterworks

FIELD Water systemsSEED 638271SHIFT Golden hour
Alpine catchment · 1,480 m

Keep the terraces flowing.

Balance reservoir, pump power and crop demand.

CLOUD COVER 62% · WIND 3.4 m/s · ROOF CATCHMENT ACTIVESystem ready
00:00 / 01:40
Delivery flow
— L/s
At greenhouse header
Total head
— m
Static lift + tank level
Upper tank
— m
Reserve line 1.25 m
Energy used
— kWh
Electrical input
Water delivered
— m³
Cumulative shift total
Source reserve
— %
Lower reservoir estimate

Station controls

Adjust the operating point · values update live

Live telemetry

Measured state and constant-rate analytic reference

1/120 s solver
Upper tank level— live · · · analytic
Flow & electrical powerflow / power

Shift timeline

Events, conditions and operating decisions

0 / 7

Operating decision · power window

Pick one response. The choice changes the live controls and the trade-off.

Start the simulation to begin the morning shift.
THE SCIENCE · model, equations & assumptionsApproximate model

The model solves a simplified operating point for a centrifugal pump, then advances the upper tank by conserving water volume. Flow is shown in L/s; calculations use SI units.

Pump curve: Hₚ = Hmax · n² − Kₚ · Q²
System curve: Hₛ = Hstatic + Kₛ · (Q/a)²
Q = √[(Hmax·n² − Hstatic) / (Kₚ + Kₛ/a²)]
Source: dVs/dt = R − Qpump
Tank: dVt/dt = Qpump − Qdemand − Qoverflow
dh/dt = (dVt/dt) / A
Hydraulic power: Pₕ = ρ g Q H
Electrical power: Pₑ = Pₕ / η

Units: Q in m³/s, H and h in m, A in m², volume in m³, power in W, energy in kWh, ρ = 1,000 kg/m³, g = 9.81 m/s².

Assumptions:

  • Constant cross-section, well-mixed upper tank and incompressible water.
  • The pipe resistance is approximate and proportional to f·L/D⁵; it is a lumped Darcy-inspired calibration.
  • Catchment recharge enters the lower source reservoir; demand is an imposed outflow.
  • The source-flow cap represents a simple intake constraint.
  • Weather, sky and particles are visual atmosphere, not a meteorological solver.

Honest simplifications: no water hammer, cavitation, air entrainment, temperature-dependent properties, detailed motor transients or real pump maps. Coefficients and events are illustrative, not engineering guidance. “Analytic” graph line assumes the current flow and demand remain constant from the starting level; it is a reference, not a forecast.