CONTINUITY + BERNOULLI · TEXTBOOK
vₜ = v₁ / r² · pₜ* = p₁ + ½ρ(v₁² − vₜ²) − ½ρK vₜ²
r = Dₜ/D₁ is the throat-to-inlet diameter ratio. The asterisk marks the single-phase pressure extrapolation. If pₜ* falls below the liquid vapour pressure pᵥ, the single-phase solution is no longer physically valid and a vapour cavity is expected.
Vapour pressure
Water vapour pressure is calculated with the Antoine relation, log₁₀(P/mmHg) = 8.07131 − 1730.63/(233.426 + T), for the selected temperature range. Absolute pressure is used throughout.
Pressure recovery
In the diffuser, the ideal pressure rises as the tube area expands and velocity falls. The cloud is drawn where the single-phase pressure profile lies below vapour pressure; the bubbles shrink as the pressure recovers.
What is simplified
The liquid is incompressible and one-dimensional, the flow is steady at each setting, and the loss coefficient is lumped upstream of the throat. The diffuser is treated as an ideal pressure-recovery section.
What is illustrative
The bubble sizes, cloud texture and collapse animation are scaled artwork, not a resolved bubble-dynamics calculation. Real inception depends on nuclei, dissolved gas, surface condition, turbulence and three-dimensional flow. The model does not predict erosion or material damage.
Independent numerical checks
LIVE · PERCENT DIFFERENCE
Continuity: inlet vs throat flowPASS · 0.00%
Bernoulli: two pressure formsPASS · 0.00%
Antoine vapour pressure vs textbookPASS · 0.00%
Onset bisection vs closed formPASS · 0.00%
Water density at 20 °C vs textbookPASS · 0.00%
Reference relations: Bernoulli’s equation, conservation of mass, and the Antoine vapour-pressure correlation for water. Default fluid properties approximate textbook water near 20 °C; other control combinations are illustrative. Not an engineering design tool.