BÉNARD LAB
THERMAL CONVECTION OBSERVATORY · MYSIMULATOR.UK
LIVE INTEGRATIONSEED 5DD2262A5259A8F5
VIRTUAL FLUID CELL / 3D FIELD VIEW
Convection chamber ● MODEL ACTIVE
X HORIZONTAL PERIODIC DOMAIN / Z LAYER DEPTH
HOT PLATE +ΔTCOLD PLATE
DRAG YELLOW PROBE TO INSPECT
COOL→WARM
x / H
z / H
MODEL TIME0.00 τ0.0 s model time
LIVE MEASUREMENTS / 01Modal amplitudes
X Y Z
LIVE MEASUREMENTS / 02Phase portrait · X versus Y
FIELD GUIDE / SCIENTIFIC CONTEXT

Inside the convection cell

MODEL NOTES · 2D BOUSSINESQ / 3-MODE GALERKIN
01

What is Rayleigh–Bénard convection?

Heat a horizontal fluid layer from below and cool it from above. At small temperature differences, thermal diffusion carries energy vertically and the fluid remains almost motionless. Increase the temperature difference and buoyancy can overcome viscous and thermal damping. The conductive state becomes unstable: warm fluid rises, cool fluid descends, and organised convection rolls appear. This is one of the cleanest laboratory examples of a hydrodynamic instability and a route from a simple equilibrium to nonlinear dynamics.

The competition is measured by the Rayleigh number, Ra = g β ΔT H³ / (ν κ). Here g is gravitational acceleration, β is thermal expansion, ΔT is the imposed temperature difference, H is layer depth, ν is kinematic viscosity and κ is thermal diffusivity. The Prandtl number Pr = ν/κ compares momentum diffusion with heat diffusion. For ideal stress-free boundaries, the minimum critical value is Rac = 27π⁴/4 ≈ 657.5, at horizontal wavenumber a = k/π = 1/√2. The ratio r = Ra/Rac therefore marks the onset at r = 1.

02

The reduced physics

This laboratory integrates the classical Lorenz three-mode Galerkin truncation of the 2D Boussinesq equations:

Ẋ = σ(Y − X)
Ẏ = rX − Y − XZ
Ż = XY − bZ

σ is Pr, r is the reduced Rayleigh number and b = 4/(1+a²) encodes the selected roll geometry. X represents convective circulation, Y the horizontal temperature contrast and Z the distortion of the mean vertical temperature profile. A fourth-order Runge–Kutta integrator advances the state with bounded substeps.

03

How to operate the lab

Choose one of the five experiments. Adjust r, Pr and a with the sliders; presets restore conductive, steady-roll or chaotic reference conditions. Play, pause, reset and change model speed at any time. Drag the yellow probe over the fluid sheet to read the reconstructed modal temperature, anomaly, streamfunction and velocity. Drag elsewhere to orbit the chamber; use the wheel to zoom and Shift-drag to pan. Change the field selector to inspect temperature, streamfunction, vorticity or speed.

The graphs are live outputs of the integrated state. Hover to inspect a time sample. Switch the second plot between the X–Y phase portrait and the modal Nusselt history. Capture readings in the notebook and export them as CSV. Challenges are checked against the actual model state and parameter values.

04

Five investigations

  • Instability threshold: sweep r through one and compare decay with growth.
  • Roll morphology: vary a and observe how critical Ra and b change.
  • Prandtl response: compare low- and high-Pr transients.
  • Chaotic convection: follow the phase portrait and compare nearby initial states.
  • Heat transport: track the modal Nu and compare it with the bottom-wall value Nuᵦ = 1 + 2Z.

Try to predict the result before changing a parameter. Record a baseline, alter one variable at a time, then compare the time histories.

05

From laboratory to engineering

Thermal convection matters in atmospheric circulation, ocean mixing, geothermal reservoirs, crystal growth, electronic cooling, industrial furnaces and heat exchangers. The same instability concepts help engineers understand when conduction-only estimates fail and when buoyancy-driven circulation changes heat transfer. In geophysics, related buoyancy-driven flows occur in the mantle, although their material properties and timescales differ enormously from a water cell.

The Lorenz model also became a landmark in nonlinear science. It demonstrates deterministic chaos: the equations contain no random forcing, yet nearby initial conditions can separate exponentially and long-term trajectories become difficult to predict.

06

Assumptions, limitations and glossary

Important model boundary: this is not a full Navier–Stokes CFD solver. It retains only three Fourier modes of an idealised two-dimensional Boussinesq layer with stress-free horizontal boundaries and a periodic horizontal domain. It captures onset, the symmetry-related roll equilibria, their Hopf instability and Lorenz-type chaotic dynamics, but it cannot resolve plume breakup, sidewall boundary layers, three-dimensional turbulence, realistic free surfaces or detailed material-property variation. The reconstructed field is the exact field of the retained modes; at strongly nonlinear settings it should be interpreted as a reduced-order teaching model, not a quantitative design prediction. The displayed Nusselt number is the volume-averaged retained-mode convective flux; during transients it can differ from the bottom-wall heat flux, and it is not an empirical high-Rayleigh correlation.

Glossary: Boussinesq approximation — density variations are neglected except in the buoyancy term; Galerkin truncation — a PDE is projected onto a finite set of basis modes; streamfunction — a scalar field whose derivatives define an incompressible 2D velocity; vorticity — local rotation of the velocity field; Hopf bifurcation — a steady state loses stability and oscillations emerge; Nusselt number — total vertical heat transport divided by conductive transport. Explore how boundary conditions, aspect ratio, additional Fourier modes and non-Boussinesq effects change the onset and nonlinear state.

Made with 🤖 ChatGPT · Three.js