01. An ocean current that turns with depth
Push a pond surface and the water initially follows your hand. Push a real ocean for hours and Earth's rotation changes the answer. In an idealised wind-driven ocean, surface stress diffuses downward while Coriolis acceleration turns each moving layer relative to the one above. Under suitable steady conditions, the horizontal velocity vectors shrink and rotate with depth, creating the Ekman spiral. It is not a spiral of water in space; it is a spiral traced by the endpoints of velocity vectors at successively deeper levels. The sculpture in the chamber shows those computed endpoints.
02. Operate the instrument
Choose one of the five experiments, adjust latitude, wind stress, heading, eddy viscosity and ocean depth, then run the time-dependent simulation. Drag the glowing probe on the left calibration rail to sample any depth, or click the current-profile plot. Drag the golden wind vane above the chamber to redirect the wind. Drag empty space to orbit, Shift-drag (or right-drag) to pan and use a mouse wheel or touch pinch to zoom. The compass assumes east is the horizontal x direction and north the horizontal z direction. Use Reset water to start from still conditions, +6 h to integrate a fixed duration, and the camera icon to restore the view.
03. Equations inside the chamber
The experiment uses the horizontally homogeneous rotating f-plane equations with downward depth z: ∂u/∂t = f v + A ∂²u/∂z² and ∂v/∂t = −f u + A ∂²v/∂z². Here u is eastward velocity, v northward velocity (m/s), t seconds, A vertical eddy viscosity (m²/s), and f = 2Ω sin φ is the Coriolis parameter, with Ω = 7.2921159×10⁻⁵ rad/s and latitude φ. The upper boundary carries prescribed surface stress τ: −ρA ∂u/∂z = τₓ and −ρA ∂v/∂z = τᵧ. Water density is held at 1025 kg/m³. Velocity is set to zero at the bottom, representing a stationary no-slip bed.
Each time step rotates velocity through an exact Coriolis half-step, solves diffusion implicitly with a tridiagonal linear solver, and applies a second half rotation. Time steps never exceed 480 simulated seconds, independently of the screen refresh rate. The solver uses 120 vertical finite-volume cells. This scheme is stable for the supported parameter range and does not require fabricated flow measurements.
04. Wind onset and spiral anatomy
Start Wind onset from zero velocity. Record the surface current after several simulated hours, then continue for two days. The upper layers accelerate before the deep layers because vertical momentum transfer takes time. For Spiral anatomy the lab pre-integrates a sustained wind, revealing a mature current profile. Compare the depth scale δ = √(2A/|f|) against the measured decay. That formula refers to the ideal semi-infinite, constant-viscosity, steady solution. A finite, no-slip tank does not exactly match it, especially when δ approaches the total depth. The north and east graph components show the direction reversals that a speed-only chart would conceal.