Mountain Waterworks

2D twin of the 3D mountain pump-network lab: the same hydraulics module computes friction, flow and the reservoir balance, shown as a side view with a pump-versus-system head plot.

Presets

Playback

Pump, pipe and town

Flow and pressure follow from head balance: the pump head at the given speed must equal the static lift plus the friction and minor losses plus the required outlet head. Friction uses the Darcy-Weisbach law with the Haaland formula for the friction factor. The speed slider compresses time (up to 600x).

Test actions

Model checks

The science

What is modelled

A centrifugal pump lifting water through a rising main to a hill reservoir that supplies a town. The operating point is found by iterating the friction factor and flow until the pump head equals the head needed, and the reservoir volume follows the mass balance.

Equations

  • Head balance: Hpump(Q) = z + Hout + (f L / D + K) v2 / 2g.
  • Friction: f = 64/Re for laminar flow, Haaland 1/sqrt(f) = -1.8 log10[(e/D/3.7)1.11 + 6.9/Re] for turbulent flow.
  • Reservoir: dV/dt = Qpump - Qtown - Qleak; the town is cut off below 22% fill.
  • Pump power: P = rho g Q H / eta.

Checks run in the page

  • Outlet head after the losses against the required head.
  • Numerical reservoir level against the exact piecewise-linear solution.
  • Haaland friction factor against an iterative Colebrook-White solution (or 64/Re when laminar).
  • Laminar limit f = 64/Re.
  • Continuity: velocity times open area equals the flow.

Honest simplifications

A single pipe and a fixed pump curve, constant fluid properties at 20 C, no water hammer, no pipe-network loops, and a simple efficiency curve. Not a hydraulic design tool.

What to try
  • Press Narrow old pipe and see the friction loss eat the pump head, so the flow falls and the reservoir drains.
  • Tick Main burst and watch the exact line and the numerical line separate after the leak changes.
  • Throttle the valve: the operating point moves up the pump curve.
Reservoir fill: numerical and exact
Pump inflow against delivered flow plus leak
Pump head and system head (operating point)
Service, efficiency, valve and reserve