A trompe uses falling water to entrain air through side ports. The bubbles travel down the pipe, separate in a wind chest, and leave as compressed air. The water seal supports the chamber pressure. Historic trompes supplied blast air to Catalan forges.
Governing model
- Water flow: H = [1 + K + fL/D] v² / 2g. Darcy–Weisbach losses; turbulent friction from the Haaland correlation.
- Pressure ceiling: pmax = min(ρwghseal, 0.88ρwgH). The 0.88 transfer factor is illustrative.
- Air entrainment: Qa,in = λQw√(1 − p/pdrive). The opening-to-entrainment relation is an illustrative empirical closure.
- Air chamber: dp/dt = Patm(Qin − Qout)/V, integrated with fixed-step RK4 under an isothermal ideal-gas assumption.
- Outlet: compressible isentropic orifice flow with γ = 1.4 and Cd = 0.70 (illustrative discharge coefficient).
- Efficiency: η = PatmQout,free ln(Pabs/Patm) / (ρwgQwH). Isothermal useful-air power divided by hydraulic input.
Constants & simplifications
Textbook constants: g = 9.80665 m/s², ρw = 998.2 kg/m³, μw = 1.002 mPa·s, Patm = 101.325 kPa, T = 293.15 K, Rair = 287.05 J/(kg·K). Pipe roughness, minor-loss coefficient, separator volume (0.14 m³), pressure-transfer factor and entrainment closure are illustrative. Water flow is steady and the downcomer length is set equal to the driving head (L = H); dissolved-air effects, bubble-size distribution, heat exchange, pipe elasticity and transient water hammer are omitted. The model is educational and does not predict a specific historic installation.
Illustrative educational model, not affiliated with any real institution or manufacturer.