Governing model
Let x be cable extension measured from the unstretched length, positive downward relative to the hook. Before take-up, the load is in free fall and the hook rises at constant speed.
ẍ = g (slack line)
Once the line is taut, it is represented as a one-sided Kelvin–Voigt element:
T = max(0, kx + cv)
m ẍ = mg − T
The damping coefficient is c = 2ζ√(km). The line breaks if its calculated tension exceeds the selected illustrative rating. After a break, the load is no longer supported by the cable.
Independent checks
- Take-up time: the RK4 event time is compared with the free-fall solution t = (√(u² + 2gs) − u)/g.
- First peak: the intact-line RK4 result is compared with the closed-form underdamped oscillator solution.
- Energy: the mechanical-energy change plus viscous dissipation is compared with the initial energy up to the first peak.
What is simplified
The crane structure is a visual reference, not a flexible-body model. The line is a single axial spring and dashpot; real wire ropes have construction-dependent stiffness, hysteresis, bending effects and changing geometry. The hook rises at constant speed, the load begins at rest, and the model omits sheaves, rope mass, wind, structural vibration, load swing and operator control. The failure threshold is an illustrative tension limit, not a lifting recommendation.
Constants: Earth gravity g = 9.81 m/s² is textbook. The numerical integration step and rig geometry are scaled for a responsive exhibit. Slider values, ratings and presets are illustrative, not equipment data.
Educational mechanics model only. It is not a lifting plan, engineering certification or safety assessment.